background image

3

© 2013 Monte Carlo Fan Company

9/1/2013

ON

OFF

ON

OFF

P

reparation

Warning

: Before starting assembly of this product, please disconnect 

power to area and familiarize yourself with the safety information 

provided on page 2.

Determine mounting method to use. 
 

A - Downrod Mount

 B - Angle Mount
 Important: If using the angle mount, check
 to make sure the ceiling angle is not steeper
 than 18º.

Importan

t: If using the angle mount, make sure open end of mounting 

bracket is installed facing the higher point of the ceiling.
 C - Flushmount
Note: Flushmount is not available with vaulted ceiling.

Installation Instruction

Before you begin installing the fan, Switch power off at Service panel 

and lock service disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting means cannot 

be locked, securely fasten a warning device, such  as a tag, to the 

service panel. (Fig. 1)

Before installing this fan make sure the outlet box is properly installed to 

the house structure. To reduce the risk of fire, electric shock, or 

personal injury, mount to outlet box or supporting system acceptable 

for fan support (Mounting must support at least 35 lbs). (Fig. 2)

Use metal outlet box suitable for fan support and use only the screws 

(and may be with flat washers and lock washers) provided with the outlet 

box  (must support 35 lbs). Before attaching fan to outlet box, ensure 

the outlet box is securely fastened by at least two points to a structural 

ceiling member (a loose box will cause the fan to wobble). Remove the 

two outlet box screws provided with the box, aligning the holes of the 

mounting bracket with the holes of the outlet box. Reinstall the 2 outlet 

box screws securely. (Fig. 2-1)

 

A

B

C

Fig. 1

Fig. 2

Fig. 2-1

Mounting

bracket

Содержание 5BHM60 Series

Страница 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Страница 2: ...e Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building st...

Страница 3: ...n the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Fig 1 Before installing this fan make sure the outlet box is properly installed t...

Страница 4: ...e and downrod until point appears on the other side and insert keeper pin on cross pin Pull the downrod up tight against the cross pin and then evenly tighten the downrod set screws on motor housing y...

Страница 5: ...g the canopy over the mounting bracket hook Use one of non slotted holes on the rim of the canopy Fig 5 2 Safety Cable Installation For Canadian installation and for USA fan and light kit combinations...

Страница 6: ...wire connector separately with electrical tape as an extra safety measure Canopy Installation Partially loosen 2 of the set screws on mounting bracket corresponding to the slotted holes on the canopy...

Страница 7: ...s shown Connect the plug from fan to the plug from switch housing aligning the claps and make sure plugs connected securely Fig 10 1 Remove 4 set screws from top switch housing keep screws Align the l...

Страница 8: ...LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0D...

Страница 9: ...Sep 2013...