Remote Controller Operation

Remove the battery cover from the remote control transmitter and install 

batteries. Replace the cover. This remote uses 2 1.5V/AAA batteries.

Note

: If not using for long periods of time, remove battery to prevent 

damage to remote transmitter, and store the remote transmitter away from 

excess heat or humidity  

Dimming, Non Dimming Setting (Only available for fans with light) 

In the dimming mold, it is a light dimming selection and it is to be used with 

dimmable luminaries. The remote controller is set with dimming function at 

factory. 

In ON/OFF (non-dimming mold), it is for light ON/OFF only (non-dimming 

function).

  

The buttons on the remote control transmitter control the fan speed and light as follows.

 Fan speed

1 = minimum speed          2 = low speed      3 = medium low speed     

4 = medium speed         5 = medium high speed       6 = high speed

      

This button turns the fan off.

      

Forward

/

Reverse button- This button is to control direction of fan rotation. Press once

     to change direction of the fan rotation. Fan must be running to reverse.        
     Light button- Press this button to turn light on or off.
     Light button- Press this button to desired brightness, dim to bright.
     Light button- Press this button to desired brightness, bright to dim.

Note

: light buttons is for the fan installed with a light. 

     Breeze 
Press the Breeze button, the fan will operate at high speed (6

th

) for 30 seconds, then automatically 

change to 5

th

, 4

th

, 3

rd

, 2

nd

, 1

st

 at intervals of 30 seconds, and then change it from Low speed (1

st

) to 

2

nd

, 3

rd

, 4

th

, 5

th

, 6

th

 repeat the cycle until the breeze mold is canceled.

Breeze mold can be erase by pressing the buttons of power or speed control.  

Note

: This remote controller has auto resume function, the fan and light will maintain the last setting if 

turned off with exception of the Breeze mold. 

Battery cover

DIM (D)

ON/OFF (O)

SET

SET

1

0

1

0

1

0

Universal Mode and Learning Mode

There are “Universal Mode” and “Learning Mode” (marks “0” and “1”) with the remote controller. 
If choosing “

Universal Mode

”, simply place dip (code) switch at LOWER position (mark “0”). Your fan with the 

remote controller is ready to use. 

Note

: If using universal mode, your fan can be controlled with other remote transmitters with the same setting.

To control the fan with specific remote transmitter, choose “

Learning Mode

” by placing the dip (code) switch 

at UPPER (mark “1”) position and then make learn function setting as below.

Learn Function Setting

Restore power to your fan, press and hold the “SET” button to pair the Transmitter and receiver. You must 

press the ‘SET” button within 60 seconds of restoring power to the fan.

Note: 

Fan will operate at minimum speed and light will blinks (If the fan installed with a light) after the setting. 

Note

: If the power is on already, you must turn the power off then turn the power back for remote control 

setting.

Note

: If reset the dip switch to “0” position (universal mold). It has to be paired again, run the learn function 

setting. 

 

Содержание 3ROZR52 Series

Страница 1: ...E RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3ROZR52XXX Series Fan cETL Model NO 3...

Страница 2: ...e building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object...

Страница 3: ...ort at least 35 lbs Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is s...

Страница 4: ...are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections...

Страница 5: ...ews securely Attach canopy bottom cap onto canopy by aligning its notch with the screws on mounting bracket and twist clockwise till tight Attach a blanking plate by locating dimples in light pan with...

Страница 6: ...gh speed 6th for 30 seconds then automatically change to 5th 4th 3rd 2nd 1st at intervals of 30 seconds and then change it from Low speed 1st to 2nd 3rd 4th 5th 6th repeat the cycle until the breeze m...

Страница 7: ...agnetic metal materials by a magnet built in the transmitter Wall mount cradle Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is stil...

Страница 8: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a poin...

Страница 9: ...Mar 2021...

Отзывы: