background image

5

© 2018 Monte Carlo Fan Company

08/2018

13

14

15

16

17

18

Lift Canopy allowing the 2 studs to protrude 

through the canopy.

Install knurled nuts as shown. Tighten the 

knurled nuts securely. The canopy should 

adjust for any irregularity in the ceiling or 

Outlet box.

Make sure the studs protruding from the 

bottom of the Mounting bracket are installed 

with threads all the way through the bracket.    

Loosen 2 and remove 1 preassembled 

screw from the plate on motor. Save 

screw for later use. 

Connect white wire from fan to white wire 

from LED light fixture and then connect 

blue (or black) wire from fan to black (or 

blue) wire from LED light fixture.   

Attach light pan onto the plate on motor, 

aligning the keyhole slots on the light pan 

with the preassembled screws on the 

plate. Twist clockwise till lock.

Reinstall the screw. Tighten all screws 

securely.

Remove 3 set screws from light pan. 

Keep screws. 

Attached inner shade onto the light pan. 

Align the holes on inner shade with the 

screw holes on the light pan. 

Install it onto the light pan with 3 set 

screws removed in the installation step 

17. 

Insert blade into the slot on flywheel.

Install blade with screws and washers 

provided, aligning each of the holes as 

shown and tighten all screws securely. 

Repeat this process for remaining blades.

Note

: Make sure the side with a label 

“This side up” is installed upward.

Stud

Blade

Plate on motor

Light pan with

LED light fixture

Inner shade

Light pan

This side up

Содержание 3BTR54 Series

Страница 1: ...DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans...

Страница 2: ...the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not...

Страница 3: ...n to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with...

Страница 4: ...be installed into the house structure beams using 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no...

Страница 5: ...LED light fixture Attach light pan onto the plate on motor aligning the keyhole slots on the light pan with the preassembled screws on the plate Twist clockwise till lock Reinstall the screw Tighten a...

Страница 6: ...e frame onto the light pan Align the holes on decorative frame with the screw holes on the light pan Install it onto the light pan with 3 set screws removed in the installation step 19 Attach the oute...

Страница 7: ...ht ON OFF only non dimming function Fig 1 Caution If the remote receiver has been wired with fan turn power off by wall switch before switch DIM and ON OFF selection DIM ON OFF Fig 1 Wall cradle insta...

Страница 8: ...SETTING and OPERATION 2 Learn function setting Restore power source to your fan press and hold the OFF button for at least 4 seconds You must press the OFF button within 60 seconds of restoring power...

Страница 9: ...ycle from bright to dim to bright until button is released when the receiver is set at DIM position Light will maintain last setting if turned off Note Dimming function is not available if the dimming...

Страница 10: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point...

Страница 11: ...Sep 2018...

Отзывы: