Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must 

be installed securely, failure to install them 

will result in serious injury.

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 20º. Longer downrod 

may be necessary allowing the fan blades 

to rotate without obstructions.    

Safety cable must be installed into the 

house structure using 3” lag screws, 

washers, and lock washers provided, 

required for outdoor applications and in 

Canada (All fans installed in Canada), and 

for USA fan and light kit combinations 

over 35lbs. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

Make wiring connections using wire 

connectors provided as indicated above.  

White from fan to White from remote 

marked to motor N. Black from fan to Black 

from remote marked to motor L. Blue from 

fan to Blue from remote marked FOR LIGHT. 

White 

(Neutral)

 from house to White from 

remote marked AC IN N. Black 

(Live) 

from 

house to Black from remote marked AC IN 

L. Connect all green grounded wires to 

Grounded wire from House. Make sure that 

no filaments are outside of the wire 

connectors.
Insert the remote receiver into mounting 

bracket.

Caution

: The installation has to be 

complete before operate the fan.

After making the wire connections, the 

wires should be spread apart with the 

grounded conductor and the 

equipment-grounding conductor on one 

side of the outlet box and ungrounded 

conductor on the other side of the outlet 

box. The splices after being made should 

be turned upward and pushed carefully up 

into the outlet box.  

      

Partially loosen one and remove one 

preassembled step screw from mounting 

bracket (Do not remove the other set 

screws). Save the screw.

Lift canopy up, aligning its keyhole slot 

with the preassembled step screw on 

mounting bracket and twist clockwise to 

lock in place. Reinstall the other step 

screw and tighten the screws securely.

Attach canopy bottom cap onto canopy 

by aligning its holes with the step screws 

on mounting bracket and fix it with the 

magnet embraced. 

Tab

Slot

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Grounded

wires

Ungrounded

wires

Tab

Wall switch

White

White

White

Black

Black

Black

Blue

Power

source

Green/Ground

Receiver

Cross pin

Keeper pin

Step screw

Step screw

Содержание 3AVLCR54XXD Series

Страница 1: ...AME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3AVLCR54XXXD Series Fan CUL Model N...

Страница 2: ...ockouts in the outlet box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of p...

Страница 3: ...for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a struc...

Страница 4: ...nockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above White from fan to White from remote marked to motor N Black from fan to Black from remote marked to...

Страница 5: ...ure plugs connection clasped together firmly Attach LED light fixture onto the light pan aligning the keyhole slots on the LED light fixture with the preassembled screws on the light pan Twist clockwi...

Страница 6: ...in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow Note Reverse switch must be set either way completely If the reverse s...

Страница 7: ...be erased by pressing either the power or speed control buttons Note This remote controller has auto resume function the fan and light will maintain the last setting if turned off with exception of t...

Страница 8: ...reset power turn the power off then turn the power back on and follow the Universal Mode or Learn Mode remote control settings 3 If two or more fans in the same remote signal range are on the same pow...

Страница 9: ...ting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this l...

Страница 10: ...Jun 2021 Dec 2021 update step 12 with step screw...