background image

iii

WARNING - Liquid: Avoiding Electrical Shocks 

Do not operate your Monster

®

 PowerSource

 if liquid of any kind is spilled onto or inside the unit. 

Do not operate your Monster PowerSource near rain or water that’s spilled or openly exposed (e.g., bathtub, kitchen 
or bathroom sink).

WARNING - Power Cord Safety 

A. When routing your Monster PowerSource AC power cord, do not place it near heavy foot traffic 
areas (e.g., hallways, doorways, and kitchen floors).

 Do not create a trip hazard with the power cord.

B. If your power cord’s protective jacket begins to rip or fray, exposing the internal wiring, 
shielding, etc., disconnect it from the PowerSource and discontinue use of the Monster PowerSource 
immediately

.

WARNING - Proper Cleaning

In general, the only cleaning necessary for your Monster PowerSource is a light dusting. 

Unplug your component from the wall outlet before cleaning it. Do not use any type of liquid or aerosol cleaners.

MANUL_HTPS_7000_Q3bn.indd   Intro:v

MANUL_HTPS_7000_Q3bn.indd   Intro:v

4/4/06   3:08:18 PM

4/4/06   3:08:18 PM

Содержание Reference PowerSource HTPS7000

Страница 1: ...Owner s Manual Q3 MANUAL_HTPS_7000_Q3bn indd Bem 11 7 05 100 K Jenny Home Theatre Reference PowerSource MANUL_HTPS_7000_Q3bn indd Cover 1 MANUL_HTPS_7000_Q3bn indd Cover 1 4 4 06 3 08 16 PM 4 4 06 3...

Страница 2: ...Minds Behind the Monster PowerSource 3 Hookup Guide 4 Grounding Your Cable TV Satellite Dish and Antenna Connections 16 HTPS 7000 Features 17 Troubleshooting 22 Frequently Asked Questions 26 Appendix...

Страница 3: ...an extension cord to make it fit into a two prong outlet Do not attempt to defeat the grounding feature by using a 3 to 2 prong adapter Instead call a local electrician to install a properly grounded...

Страница 4: ...ays doorways and kitchen floors Do not create a trip hazard with the power cord B If your power cord s protective jacket begins to rip or fray exposing the internal wiring shielding etc disconnect it...

Страница 5: ...Monster PowerSource is not operating properly do not remove any part of the unit cover etc For repair Unplug the unit and consult this owner s manual for service information CAUTION Exposure To Heat...

Страница 6: ...codes for the 750 000 Limited Connected Equipment Warranty to be valid If you re not sure about your home s wiring have it checked by a qualified electrician Note to CATV Installer This reminder is pr...

Страница 7: ...ts If any noise from an electronic product plugged into an outlet gets through our Monster Clean Power noise filters and to the power line it will have to go through another filter to get to an adjace...

Страница 8: ...age 5 with balanced transformers for the best possible performance Monster Clean Power Stage 5 Five ultra advanced isolation filters including two separate digital filters for separate digital sources...

Страница 9: ...ing complex AC power problems for several years As a technical consultant for successful paper and steel mills Demian helped create several innovative AC power solutions He developed techniques to dra...

Страница 10: ...onnect a second phone cable from the HTPS 7000 OUT jack to the Pay Per View input on your DSS Receiver or DVD player Figure 1b FOR STANDARD TELEPHONE LINE PROTECTION NOT A PAY PER VIEW DEVICE A Connec...

Страница 11: ...ower on process Once the process is finished the display will show the main line voltage similar to Figure 2 Note The power on process may take up to 60 seconds since any outlet pair can be configured...

Страница 12: ...s a maximum time DELAY TIME setting will be turned off immediately once the PowerSource is switched off by pressing the front panel ON OFF button or by external signal D Set the Outlet Pair to Unswitc...

Страница 13: ...normal line voltage When setting at enable the unit will sound the alarm when the line voltage is higher than 130V or lower than 100V A Press MENU until the displays show B Press SET to toggle between...

Страница 14: ...re for abnormal line voltage When setting at enable the unit will shutdown itself when the line voltage is higher than 134V or lower than 96V A Press MENU until the displays show B Press SET to toggle...

Страница 15: ...male plug into a switched AC power outlet on a receiver or preamplifier When you turn on your receiver or preamplifier the PowerSource s outlets programmed as switched on will be turned on immediatel...

Страница 16: ...rces A Plug a 1 8 mini plug cable not supplied into the REMOTE IN DC 3 30V outlet on the PowerSource see diagram below B Plug the other end of the cable into the corresponding outlet on your component...

Страница 17: ...axial cables to connect the PowerSource to these components Protect cable TV satellite and antenna connections as follows See page 16 regarding proper grounding MANUL_HTPS_7000_Q3bn indd Main 19 MANUL...

Страница 18: ...rned off first to prevent speaker thump See STEP 2 Outlet Programming page 6 for details A Attach a Monster Power ID label to each component s power cord before you plug it into the appropriate color...

Страница 19: ...ff any component plugged into these outlets can receive power continuously as long as your PowerSource is plugged into a properly grounded 120 volt wall socket and the pair is programmed as unswitched...

Страница 20: ...B DVD If you have a DVD player plug its power cord into the corresponding DVD outlet If you are using a LaserDisc player you can also plug it into this outlet If you have a LaserDisc player and a DVD...

Страница 21: ...it when the PowerSource is turned off Plug any type of low current analog audio component preamplifier tape deck into the corresponding outlet A Attach a Monster Power ID label to each component s pow...

Страница 22: ...d by using a special grounding block attached to a cold water pipe or copper grounding rod driven into the earth Consult with a qualified electrician to verify that your outdoor connections are proper...

Страница 23: ...17 HTPS 7000 FEATURES PLEASE TURN TO PAGE 18 21 FOR DESCRIPTION OF PRODUCT FEATURES MANUL_HTPS_7000_Q3bn indd Main 25 MANUL_HTPS_7000_Q3bn indd Main 25 4 4 06 3 08 23 PM 4 4 06 3 08 23 PM...

Страница 24: ...ircuitry is functioning properly 7 Monster Clean Power LED Indicates the unit is powered on 8 Abnormal Voltage LED Indicates abnormal line voltage You should turn the unit off to protect the PowerSour...

Страница 25: ...ideo components or digital components to be connected to the analog audio outlet section However for best possible performance we recommend only plugging in low current analog audio components here 18...

Страница 26: ...ain amplifier a special filter circuit reduces noise from the AC power line that would degrade the audio performance and to optimize high current demand NOTE It does not harm low current audio compone...

Страница 27: ...he coaxial cable from your satellite dish The output connects the coaxial cable to the input of a satellite receiver 31 Antenna Coaxial Input Output The input connects the coaxial cable from your TV a...

Страница 28: ...connected causing an overload throwing the thermal circuit breaker Please note that the total power consumption of all the components powered by the PowerSource should not exceed 1800 watts Possible S...

Страница 29: ...e components Possible Cause 1 The component is plugged into an outlet programmed as switched on or switched on after delay and the PowerSource has not been turned on Possible Solutions Press the ON OF...

Страница 30: ...st possible performance plug the PowerSource into a wall outlet not an outlet on another component Possible Cause 3 The PowerSource is defective Possible Solution Please see page 31 for warranty infor...

Страница 31: ...Possible Cause The PowerSource is not plugged into a properly grounded AC outlet Possible Solution Plug the PowerSource into a properly grounded 120V outlet MANUL_HTPS_7000_Q3bn indd Main 33 MANUL_HT...

Страница 32: ...to get into other connected equipment It will not succeed however because it must go through specialized filters to get to an adjacent outlet and the noise is eliminated for the best possible sound an...

Страница 33: ...set button labeled BREAKER 15A on the PowerSource s rear panel It is possible the overload came from your high powered audio equipment If your system were to draw too much power a special circuit brea...

Страница 34: ...mance without noise entering their signal path Conducted Noise Any unwanted electrical signal conducted on the power lines supplying the equipment Current The movement of electrons through a conductor...

Страница 35: ...ceeds its average amplitude considerably Surge A large sudden change of voltage or current usually caused by the collapse of a magnetic field or by a shortened or opened circuit element Surge Protecto...

Страница 36: ...Source HTPS7000 is protected under U S Pat No 5 589 718 6 473 510 Other Patents Pending Monster Monster Cable Monster Power Clean Power Pure Power Power Source and are registered and unregistered trad...