Dimensions and Installation Information (in inches)
The Installation Space
The finished cutout width must be 30".
The cutout depth must be 25" for flush installations.
• The front face of the refrigerator fits flush with 25
"
depth
adjacent cabinets
.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
Note
: GFI (ground fault interrupter) is not recommended.
Height options
80” or * 84“
25” min. depth
30” Finished Width
Height adjustable
from 79-3/8” to 80-3/8” *
3/4”
23-3/4”
29-3/4”
1/8”
1-1/4”
4”
4”
Water Line
• A cold water supply is required for automatic icemaker
operation. The water pressure must be between 40 and 120
p.s.i.
• Route 1/4
"
OD copper or GE SmartConnect
™
plastic
tubing between the house cold water line and the water
connection location.
• Tubing should be long enough to extend to the front of the
refrigerator. Allow enough tubing to accommodate a bend
leading into the water line connection.
• Water line can enter an opening through the floor or back wall.
• Install a shut-off valve between the icemaker water valve
and cold water cupply in the home.