Monogram ZGU384NSMSS Скачать руководство пользователя страница 1

ADJUST THE REGULATOR

A.

Disconnect all electrical power at the main circuit
breaker or fuse box.

B.

Shut off the gas supply to the cooktop by closing 
the manual shut-off valve.

C.

Adjust the pressure regulator by the following
instructions:
• Unscrew the cap.
• Place your thumb against the flat side of the spring

retainer and press down to remove the retainer.

• Carefully look at the spring retainer to locate the NAT 

or LP position.

• Turn the spring retainer over so that the desired gas 

is showing on the bottom.

• Snap the retainer back into position.
• Screw the cap back onto the regulator.

1

CHANGE BURNER ORIFICES

INSTALLATION TIP: 

First remove all

orifices and then start replacing them.
This will help to prevent the possibility
that some may not be replaced.

A.

Remove the burner grates,
burner caps and burner heads.

B.

Using a 7 mm nut driver, remove
the top burner orifices. There are
two orifices per burner.
The main orifice is
located low in the center
of the burner, while the
simmer orifice is located
higher beside the center
of the burner.

2

DOWN 

FOR OFF

NAT

LP

LP

NAT

LP

NAT

NAT

LP

Gasket

Cap

Spring
retainer

L.P./propane
position

NAT position

Pressure regulator

Burner cap

Burner

head

Burner

base

Spark igniter

Main
orifice

Simmer
orifice

SAFETY INFORMATION

The pressure regulator and burner orifices are set for
natural gas operation.

To convert this cooktop from natural gas operation to 
LP operation, the regulator and burner orifices must be
converted. LP burner orifices are attached to the regulator.

CAUTION 

— The cooktop, as shipped from

the factory, is set for use with its intended gas. If you
wish to use your cooktop with the alternate gas, you
must first replace the orifices and convert the pressure
regulator.

WARNING 

— This conversion must be

performed by a qualified installer or gas supplier in
accordance with the manufacturer’s instructions and 
all codes and requirements of the authority having
jurisdiction. Failure to follow instructions could result in
serious injury or property damage. The qualified agency
performing this work assumes responsibility for the
conversion.

CAUTION 

— The following adjustments must 

be made before turning on the burner. Failure to do so
could result in serious injury. Be sure the pressure
regulator has been converted as described in Step 1.

TOOLS YOU WILL NEED FOR
 CONVERSION

Safety glasses

Small flat-head screwdriver 

(2 to 2.4 mm or 3/32" tip size, 

60 mm long)

Crescent wrench

7 mm nutdriver

Installation 

Convert Natural Gas Model ZGU384NSMSS 

Instructions

to LP Gas Operation

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: www.monogram.com

1

31-10717    

(11-08 JR)

If sold outside the U.S. and Canada:

WARNING:

If you wish to use this product

with Liquefied Petroleum (LP) gas containing greater than
10% butane, you must purchase the butane conversion
kit #WB28T10238. To order, please call 1.888.664.8403 
or 1.787.276.4051.

Содержание ZGU384NSMSS

Страница 1: ...convert this cooktop from natural gas operation to LP operation the regulator and burner orifices must be converted LP burner orifices are attached to the regulator CAUTION The cooktop as shipped fro...

Страница 2: ...the cooktop If the flame is extinguished by the air currents created by the door movement increase the flame height and test again NOTE When the burner is on the SIM setting the upper row of flames wi...

Страница 3: ...FORMATION The pressure regulator and burner orifices are set for LP gas operation To convert this cooktop from LP gas operation to natural gas operation the regulator and burner orifices must be conve...

Страница 4: ...ame is extinguished by the air currents created by the door movement increase the flame height and test again NOTE When the burner is on the SIM setting the upper row of flames will go out F Flame Rec...

Страница 5: ...ncionar con gas natural El regulador y los oricios del quemador deben ser convertidos para cambiar esta plancha de funcionamiento con gas natural a gas LP Los oricios del quemador LP est n unidos al r...

Страница 6: ...eada por el movimiento de la puerta aumente la altura de la llama y pruebe de nuevo NOTA Cuando el quemador est en el ajuste SIM se apagar la fila superior de llamas F Vuelva a revisar la llama Despu...

Страница 7: ...nto lento INFORMACI N DE SEGURIDAD El regulador de presi n y los oricios del quemador est n ajustados para funcionar con gas LP El regulador y los oricios del quemador deben ser convertidos para cambi...

Страница 8: ...ncha Si la llama se apaga debido a la corriente de aire creada por el movimiento de la puerta aumente la altura de la llama y pruebe de nuevo NOTA Cuando el quemador est en el ajuste SIM se apagar la...

Отзывы: