Operating Procedure 

 

To operate the CC-8521B, enter the valid 3-6 digit PIN code on the keypad. When the 
valid PIN code is entered, the green LED on the keypad will illuminate and the door 
lock will release. 

The keypad has a build-in visitor annunciator button. Pressing the # button causes an 
annunciator to sound in the control unit. If an external audio or visual device is 
connected, it will also activate when this button is pressed. 

If an incorrect PIN code is entered, the system will enter a penalty mode and will not 
recognize any digits for the programmed 5-60 seconds. If five successive invalid PINs 
are entered, the penalty time is set to 60 seconds until the valid PIN is entered. After 
the penalty time has elapsed, the unit will return to normal operation and entering the 
valid PIN code on the keypad will release the door. 

If the external release button has been installed, it can be used by an attendant to 
release the lock from a location on the secure side of the door. 

Diagrams and schematics are available on www.moniteq.com. 

Various alarm situations activate different sequences of sounds on the alarm in the 
control unit. If an external audio device is connected to the system, it will sound the 
same sequences as the alarm in the control unit. The table below lists these alarm 
sequences and their meaning. 

Alarm Type 

Alarm Sequence 

Silenced By 

Visitor 

Activated by # button on keypad 

 

Invalid PIN 

- - - - - 

Five short beeps 

After five short beeps 

Door Propped  ____  ____  ____ 

Continuous long 
beeps 

Door closed or time out 
set by code *23*N* 

Forced Door 

- - - - - - - - - - - - - - - -  Continuous short 

beeps 

Valid PIN or code *24*0* 

Low Battery 

-    -    -    -    -    -    - 

Chirp every 15 
seconds 

Apply AC power 

 

 

 

Содержание Crypto-Lock CC-8521B

Страница 1: ...CRYPTO LOCK Model CC 8521B Access Control System Instruction Manual Ed 11 17 Moniteq Inc...

Страница 2: ...2...

Страница 3: ...s Introduction 4 Specifications 6 Supplied Equipment 7 Functions of Controls and Indicators 8 KEYPAD 8 PROGRAMMING MODE 8 CONTROL UNIT 8 Installation 9 Setup 10 Programming 12 Operating Procedure 14 L...

Страница 4: ...ks The control unit can house two optional 12V 7AH sealed lead acid batteries not included and maintain them at full charge Audible and visual warnings will occur when the charge level is low Security...

Страница 5: ...attery Warning Output Stand by Batteries External Annunciator Output Magnetic Lock fail safe Release Button Keypad with Status LED Electric Lock or Strike fail secure 115 230 Vac 50 60Hz Figure 1 Typi...

Страница 6: ...SPDT Form C Battery Backup 12VDC or 24VDC automatic transfer and charging batteries optional Enclosure Description 19 gauge steel powder coated paint gray color knockouts for conduit and cam lock inc...

Страница 7: ...tted Sheet Metal 6 Hold Control Unit Door Closed 2 Battery Cables 18 AWG Black Red Connect Batteries to Board 2 Fuse 5 x 20MM 4A Slo Blo Spares 4 Hex Nut 8 Keypad Mounting 2 Acorn Nut 8 Keypad Mountin...

Страница 8: ...id programming entry CONTROL UNIT Penalty LED illuminates when invalid PIN penalty feature is activated AC Power LED illuminates when the system is AC powered Battery Power LED illuminates when the sy...

Страница 9: ...or does not need to be locked the two supplied 6 x screws can be used in the holes on the door edge to hold it closed Note all cables passing through the knockout holes in the enclosure must be protec...

Страница 10: ...switch to LIMIT when used with Brute electric lock or a similar heavy duty solenoid operated lock Set this switch to DIRECT when used with standard electric strikes or magnetic locks 3 Connect the pow...

Страница 11: ...11 Figure 2 Wiring Diagram...

Страница 12: ...or 5 minutes Initial Settings During a new installation or if existing settings are unknown it is recommended that the default values for all PIN and door monitoring settings be reset by entering 00 o...

Страница 13: ...hen this function is enabled the door re locks immediately after it closes regardless of the open duration setting Door Propped Alarm The door propped alarm function sounds an alarm when the door rema...

Страница 14: ...he unit will return to normal operation and entering the valid PIN code on the keypad will release the door If the external release button has been installed it can be used by an attendant to release...

Страница 15: ...15...

Страница 16: ...in cases of abuse misuse mishandling modification or repair by unauthorized persons This warranty is given in lieu of all other warranties expressed or implied Moniteq Inc is not liable for incidenta...

Отзывы: