Installation and Operating Instructions Ahti & Ukko

10. Heater maintenance history

date

procedure

Содержание Ahti 6.0

Страница 1: ...Installation and Operating Instructions Ahti and Ukko heaters 12 2017...

Страница 2: ...installation 8 5 General instructions for users of Ahti and Ukko heaters 9 Note 9 Installation cable 9 Additional connection options 9 6 Things to keep in mind when using the heater 9 Preheating 9 Sa...

Страница 3: ...e sauna should be supervised Benches and floors may be slippery therefore move in the sauna with caution Do not go to a hot sauna under the influence of narcotic substances alcohol drugs narcotics etc...

Страница 4: ...4 Installation and Operating Instructions Ahti Ukko 2 Ahti and Ukko heaters Ahti heater 6 0 kW and 8 0 kW Ukko heater 6 0 kW 8 0 kW and 10 5 kW...

Страница 5: ...mponents 1 Background stone 2 Small heater stones 3 Steel shelf 4 Side stone stainless steel 5 Front and side bottom stones stainless steel 6 Overheating protector reset switch 7 Thermostat 8 Time swi...

Страница 6: ...Attach the heater to the wall with screws Observe the safety distances between the heater and any inflammable material in accordance with Table 4 4 see Figure 3 3 when installing the heater 3 Install...

Страница 7: ...he shelf see Figure 3 6 5 Attach the background stone see Figure 3 7 6 When stacking the stones ensure that you do not place small heater stones among the resistors or on top of the ventilation grill...

Страница 8: ...ed quantity of stones Table 4 2 6 0 kW 8 0 kW 10 5 kW A 220 220 365 B 310 310 435 C 275 275 310 D 140 206 260 E 615 615 780 F 103 130 Attachment points in corner installations Table 4 5 Attachment poi...

Страница 9: ...o when the heater blocks are replaced In the first preheating the heater will be heated for twenty minutes with the temperature control set to the middle position Let the heater cool down completely b...

Страница 10: ...wood tile or concrete surfaces or the walls are made of logs the heater power needs to be increased For every uninsulated square metre the heater power need increases by the same amount as if increas...

Страница 11: ...11 Installation and Operating Instructions Ahti Ukko Heating control Indicator Heater on 7 Wiring diagram...

Страница 12: ...ing up after two hours When the power has been switched on the heater will remain on for a maximum of 4 hours After that the power will be switched off automatically You can switch the power off soone...

Страница 13: ...n If necessary contact the dealer or manufacturer Warnings Due to a risk of fire do not use the sauna to dry clothes or laundry Exercise caution with a hot heater since the heater stones and metal par...

Страница 14: ...l Small pebbles or pieces may come off the soapstones used in the heater As this is not a failure of the organic material but a natural feature that cannot be predicted at the time of manufacturing th...

Страница 15: ...15 Installation and Operating Instructions Ahti Ukko 10 Heater maintenance history Date Procedure...

Страница 16: ...Technical support info mondex fi Premec Oy Kettukallionkatu 4 84100 Ylivieska Finland info mondex fi www mondex fi...