NICE5000 User Manual 5 System Commissioning and Functions
- 83 -
2. After ensuring that control of door open/close is normal, check whether the door open/
close signal feedback from the door machine controller is normal.
a. Check the NO/NC states of the door input signals by observing the input indicators on
the CTB, as listed in the following table.
Table 5-1 NO/NC state of the door input signals
Door
State
Signal Input Point
NO Input Signal
NC Input Signal
Indicator State
FL-00
Setting
Indicator State
FL-00
Setting
Door
open limit
X3 (door open limit 1) When the signal
is active, the
corresponding
input indicator is
ON.
Bit2 = 1 When the
signal is
active, the
corresponding
input indicator
is OFF.
Bit2 = 0
X4 (door open limit 2)
Bit4 = 1
Bit4 = 0
Door
close limit
X5 (door close limit 1)
Bit3 = 1
Bit3 = 0
X6 (door close limit 2)
Bit5 = 1
Bit5 = 0
For details on the setting of FL-00, see the description of FL-00 in Chapter 7.
b. Check whether the door open/close limit signal received by the system is correct.
Control the door to the open or close state manually and view the value of FU-26. If the
following screen is displayed, it indicates that the door machine controller feeds back
the correct door open and close signals.
Figure 5-3 Door open and close limit monitoring signals
1
2
3
4
5
Door 1
open limit
Door 1
close limit
5.3 Riding Comfort
The riding comfort is an important factor of the elevator's overall performance. Improper
installation of mechanical parts and improper parameter settings will cause discomfort.
Enhancing the riding comfort mainly involves adjustment of the controller output and the
elevator's mechanical construction.
Содержание NICE 5000
Страница 1: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...
Страница 15: ......
Страница 16: ...1 Safety Information and Precautions...
Страница 23: ...1 Safety Information and Precautions NICE5000 User Manual 22...
Страница 24: ...2 Product Information...
Страница 34: ...3 Mechanical and Electrical Installation...
Страница 71: ...4 Use of the Commissioning Tools...
Страница 79: ...5 System Commissioning and Functions...
Страница 99: ...6 Function Code Table...
Страница 130: ...6 Function Code Table NICE5000 User Manual 128...
Страница 131: ...7 Description of Function Codes...
Страница 201: ...8 Troubleshooting...
Страница 220: ...8 Troubleshooting NICE5000 User Manual 218...
Страница 221: ...9 EMC...
Страница 230: ...9 EMC NICE5000 User Manual 228...
Страница 233: ...5000 5000 User Manual 5000 Integrated Elevator Controller Data code 19010314...