8
HE Performance Testing
All at 2.4-2.5 bar with motive water flow approx. 0.65 lpm + brine draw of approx. 0.2 lpm.
Injector: Black 0000 with black throat
BLFC: 0.2usgpm
DLFC: 1.5usgpm
MAQ001HE/E - MiniAqua HE (MN0913)
4.26 litres saturated brine @ 6 lpm flow rate @ 480ppm
Virgin resin full capacity @ 1500 litres
Thereafter average capacity after 3 tests @ 930 litres
MIDM002HE/E – Midi HE (MN0916)
5.68 litres saturated brine @ 8 lpm flow rate @ 480ppm
Virgin resin full capacity @ 2900 litres
Thereafter average capacity after 3 tests @ 1460 litres
MAS003HE/E – Master HE (MN0922)
8.52 litres saturated brine @ 10 lpm flow rate @ 480ppm
No virgin resin capacity test undertaken as MN0913 and MN0916 resin used from previous tests
Average regen capacity after 3 tests @ 2100 litres
MATR004HE/E – Matrix HE (MN0935)
14.2 litres saturate brine @ 8 lpm flow rate @
440ppm
Virgin resin full capacity @7250 litres
Thereafter average capacity after 3 tests @ 3840 litres
COMPANY LABEL
Unit
Resin
Litres
Backwash mins
Every 7th regen
Brine
Draw
mins
Rinse mins
Water use
per
regeneration
Mini AQUA HE
CS100 HE
9x13
9
1
50
2
43.4
Midi HE
CS150 HE
9x16
12
1
60
3
51.9
Master HE
CS200 HE
9x22
18
2
90
4
80.3
Matrix HE
CS300 HE
9 x 35
30
6
68
6
139.4