5
Mix gently after each 5 drops.
Count the drops needed until the colour of the sample in the test tube changes from a dark red to a dark
blue/green.
You need this figure for when SET WATER HARDNESS (step XX)
Setting the electronic controller
Turn on power and the softener display will say WELCOME.
The Display is a 2 line display showing both the Model No and
also Time and Hardness. The Time and Hardness will alternate
every 10 seconds.
To finalise commissioning of the softener, you need to set
both Time (24hr clock in hours and minutes) and the water
hardness as determined by the amount of drops in your water hardness test.
Setting the time of day
Wait until display shows Time of Day.
If Time of Day is correct, skip to ‘SET HARDNESS’.
Press Up button to show flashing Hours. Please note it is a 24hr clock.
Press Up or Down button to set Hours.
Press @ to confirm Hours.
After confirming Hours with (), display will show minutes flashing.
Use Up and Down button to set Minutes.
Press @ to confirm Minutes.
Set water hardness
Wait until display changes to Hardness.
Press ‘Up’ Button to show Set Hardness with no flashing.
Use ‘Up’ Button to set number as determined by your water hardness test.
Press @ to confirm setting.
Flush the softener
Add water until there is approximately 1” (25mm) of water above the grid plate. If the tank does not have a
grid, add water until it is above the air check in the brine tank. Do not add salt to the brine tank at this time.
If the unit has a bypass valve, place it in the bypass position.
Slowly turn on the main water supply.
Open a cold soft water tap nearby and let water run a few minutes or until the system is free of foreign
material resulting from the plumbing work. Close the water tap when water runs clean.
Place the bypass in the service position and let water flow into the salt tank. When water flow stops, slowly
open a cold water tap nearby and let water run until air is purged from the unit. Then close the tap.