Страница 1: ...Instruction Manual RLS and RLS24 Rugged Laser Sensors 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com ...

Страница 2: ... km away NEVER point any laser towards aircraft or vehicles it is unsafe and illegal Read and follow all instructions in this manual carefully and retain this manual for future reference Do not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifications stated This instrument is not user serviceable For techn...

Страница 3: ...able online at www monarchinstrument com Monarch Instrument holds the following US trademarks and registrations all rights reserved illumiNova Nova Pro Nova Strobe DataChart Track It TABLE OF CONTENTS 1 0 OVERVIEW 1 2 0 CONNECTION DETAILS 2 3 0 OPERATING INSTRUCTIONS 2 4 0 SPECIFICATIONS 5 4 1 Dimensions 6 4 2 Environmental 6 4 3 Compliance 6 5 0 ACCESSORIES 7 ...

Страница 4: ... mounting The RLS and RLS24 are supplied with a removable 3 m 9 8 ft cable with a watertight M12 4 Pole Female connector on one end and a 3 5 mm 1 8 inch male stereo plug RLS P or RLS24 P or 4 tinned wires RLS W or RLS24 W on the other end An optional 25 ft 7 6 m extension cable EC 25P is available with a female socket for the plug on one end and a 3 5 mm 1 8 inch male stereo plug on the other for...

Страница 5: ... to the sensor is via the watertight M12 connector on the end of the sensor The sensor may be ordered with one of two cables the P with a 3 5 mm stereo connector or the W with tinned wires as shown below RLS W with wires RLS P with plug ...

Страница 6: ... sensor power supply SPSR IM with BNC output is available for those applications that require a separate power source for the sensor RLS P only The RLS Rugged Laser Sensor can detect a reflected pulse from a target consisting of T 5 Reflective Tape or high contrast color differences such as black and white at distances up to 25 feet 7 6 m from the rotating object and angles up to 60 degrees For mo...

Страница 7: ...ch from the reflective target to avoid false triggering The green LED On Target Indicator will blink at the input frequency rate when the RLS is properly aimed Note The green LED On Target Indicator will blink on off at slow speeds and remain on steady at high speeds Note Optical speed sensors require environments that are clean and free of mist steam dirt oil and other contaminants to function pr...

Страница 8: ...typical at 2 m Laser Diode Life 8 000 operating hours MTBF 1 year warranty On Target Indicator Green LED on tube body active when pulse present Operating Range Up to 7 6 m 25 ft and 60 offset from target Power Requirements RLS W and RLS P 4 15 V dc 20 0 5W RLS24 W and RLS24 P 10 24 V dc 20 0 5W Output Standard Open Collector with internal pull up resistor 5600 ohm to supply voltage positive pulse ...

Страница 9: ...cables Operating Temperature 10 C to 50 C 14 F to 122 F Storage Temperature 40 C to 80 C 40 F to 170 F 4 3 Compliance CE Compliant Low Voltage Directive LVD 2014 35 EU Electromagnetic Compatibility Directive EMC 2014 30 EU Restriction of Hazardous Substances RoHS 3 Directive 2015 863 EU ...

Страница 10: ... 8 in male stereo plug PN 6180 085 RLS w Cable 3 m cable with M12 connector to tinned leads PN 6180 084 RLS Nut Jam Nut M20 x 1 5 x 10 mm Two required to secure to Mounting Bracket PN 1053 0189 001 RLS Mount Mounting Bracket 90 slotted PN 1052 4350 112 Reflective Tape T 5 single pack 5 feet PN 6180 070 T 5 2 pack 5 feet each PN 6180 069 T 50 50 feet PN 6180 072 T 5WP waterproof 5 feet PN 6180 079 ...

Страница 11: ...8 This page intentionally left blank ...

Страница 12: ...Instrument is committed to excellence and quality in manufacturing sales and service The Professional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portable Tachometers Portable Strobes Frequency Converters Fixed Mounted Strobes 1071 4180 712 0821 Copyright 2019 2021 Monarch Instrument All rights reserved ...