7

3.2  External Input Mode

Press  the  MODE  button  (without  pressing  the  tuning  button  in 

between) until the 

EXT

 icon is displayed. An external input is required 

(TTL compatible source from a self-powered sensor).

In the 

External Input Mode

 there are no flash rate adjustments the 

user  can  make.  The  flash  rate  is  triggered  by  the  TTL  input  signal. 

This mode is used to synchronize the flash to an external event (for 

example, from an optical sensor) to stop or freeze motion for timing 

studies or balancing machines. The flash will be triggered on the rising 

edge of the external input pulse. 

The  maximum  input  is  12,500 FPM, above  which  the  strobe  will  no 

longer flash. 

3.3  Tach Mode (No Flash) – External Input Required

Press  the  MODE  button  (without  pressing  the  tuning  button  in 

between) until the 

TACH

 icon is displayed. In the 

Tachometer Mode

the  unit  will  read  the  signal  from  the  external  input  (self-powered 

sensor) and display the reading on the LCD, without flashing the lamp. 

The strobe can read up to 250,000 RPM in this mode.

4.0  USING THE STROBOSCOPE TO MEASURE RPM

The  primary  use  for  a  stroboscope  is  to  stop  motion  for  diagnostic 

inspection  purposes.  However,  the  stroboscope  can  also  be  used  to 

measure speed. In order to do this, several factors need to be considered. 

First, the object being measured should be visible for all 360° of rotation 

(e.g. the end of a shaft). Second, the object should have some unique part 

on it, like a bolt, keyway or imperfection to use as a reference point. If the 

object being viewed is perfectly symmetrical, then the user needs to mark 

the object with a piece of tape or paint in a single location, while the object 

is stationary, to be used as a reference point. 

Look only at the reference 

point.

Содержание PALM STROBE x

Страница 1: ...ction Manual PALM STROBE x Pocket Sized Portable Stroboscope 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrume...

Страница 2: ...enter the ventilation holes on the stroboscope as this may cause permanent damage and void the warranty 9 Do not allow cables extending from the unit to come into contact with rotating machinery as se...

Страница 3: ...onarch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty Coverage information is available online at www monarchinstrument com...

Страница 4: ...e has a removable rechargeable battery pack which provides up to 2 hours of continuous use depending on the flash rate This battery pack clips in and out with no tools required An optional second batt...

Страница 5: ...Indicator for Tachometer Mode and Remote Sensor in External Input Mode Lock icon shown to indicate that the strobe is locked on External Input Mode displays when mode is activated Tachometer Mode disp...

Страница 6: ...troboscope depends on the flash rate and duty cycle of operation Slower flash rates increase the operating time 2 2 Input Output Connections PALM STROBE x has a TTL Input Output phone jack on the side...

Страница 7: ...is displayed on the LCD in flashes per minute which typically is the same as RPM The PALM STROBE x has three primary operating modes Internal External Input and Tach and three functions 2 2 Recall an...

Страница 8: ...right to select which digit to change The digit blinking is the one to be changed 3 Rock the tuning button up or down to increase or decrease the value of the blinking digit The digit will stop blinki...

Страница 9: ...rate To store the current flash rate in a Preset memory location 1 Press the MODE button once The 2 2 icon will be displayed 2 Press the MODE button a second time without pressing the rubber tuning b...

Страница 10: ...tton in between until the TACH icon is displayed In the Tachometer Mode the unit will read the signal from the external input self powered sensor and display the reading on the LCD without flashing th...

Страница 11: ...iewing a shaft with a single keyway you will see one stationary image of the keyway at the actual speed and at 1 2 1 3 1 4 etc of the actual speed You will see 2 images of the keyway at 2 times the ac...

Страница 12: ...y tricked into seeing a stopped image by a stroboscope when the flash rate is slower than 300 FPM Therefore a stroboscope image is difficult to use below 300 FPM for inspection or to measure RPM 5 0 L...

Страница 13: ...into place see Figure 6 Make sure the lamp is in straight and centered in the reflector hole L 1905 Lamp Note Older PALM STROBES and flashtubes may have a red dot on the flashtube and connector to ind...

Страница 14: ...batteries before use and allow 3 5 cycles of charging and discharging for batteries to reach full capacity The enclosure contains control electronics to properly and safely charge the batteries Never...

Страница 15: ...ort time When the battery charge is further depleted the strobe will stop flashing the Low Battery icon will be displayed and then the strobe will completely shut off When the Low Battery icon is disp...

Страница 16: ...o the wall outlet CAUTION Use of rechargers other than the one supplied PSC 2U may damage the stroboscope and void the warranty The battery module contains circuitry to control the charge The amber LE...

Страница 17: ...ve the four screws on the under side of the Battery Pack and separate the case halves exposing the battery Remove the cables from the battery and place tape over the battery terminals to prevent them...

Страница 18: ...easurements 5 to 250 000 RPM No flash Accuracy The greater of 0 1 FPM or 0 01 of reading Display Update Rate 1 second typical Trigger to Flash Delay 5 sec External Input 0 to 5 V TTL Compatible 12 V p...

Страница 19: ...cs Charge Control for rechargers PSC 2U Recharger 9 V dc 500mA Light Power 150 mJ Flash up to 3000 FPM 7 9 Watts 6000 FPM Flash Duration 10 30 microseconds typical Run Time 2 hours at 1800 FPM and 1 h...

Страница 20: ...ctive 2011 65 EU Specifications PALM STROBE x Safety This product is designed to be safe for indoor use under the following conditions per IEC61010 1 Operating Temperature 32 104 F 0 40 C Humidity Max...

Страница 21: ...mono plug to BNC connector for use with PLT200 Tachometer and stroboscopes 6280 043 PALM STROBE Holster Holster with belt loop for fit with utility belt features pouch for spare battery included with...

Страница 22: ...Input Output Cable PALM STROBE x Holster PN 6280 037 PN 6280 043 SPSR Self Power Sensor Pulse Input Cable PN 6150 020 PN 6280 032 CC 9 Mini Tripod T 5 Reflective Tape PN 6280 042 PN 6280 040 PN 6180 0...

Страница 23: ...US Patent 6 945 666 6280 022 PSC 2U Universal recharger 115 230 V ac with USA UK AUS and Euro adapter plugs 6280 028 L 1905 Replacement xenon lamp 2 pack Replacement Parts Rechargeable Battery Pack PN...

Страница 24: ...nstrument is committed to excellence and quality in manufacturing sales and service The Professional s Choice Track It Data Loggers Panel Tachometers DataChart Paperless Recorders Speed Sensors Portab...

Отзывы: