5.4.4

 

 



 

FAIL SAFE -

 Press the 

SET

 button and use the 

UP

 



 button to select whether the Alarm is FAIL 

Safe – select 

YES

, or 

NO

. Press the 

SET

 button to select the new setting or the 

RECALL

 button to 

exit without saving the settings. 

5.4.5

 

 



 

SET POINT -

 Press the 

SET

 button to display the current SET POINT value and use the buttons 

to set the required value.  Press 

RECALL

 to exit up one level  without making a  change or press 

SET

 to save the change. The edit buttons function as follows: 

RESET

 

- changes the digit being edited (blinking digit) 

UP 



 

- increases the digit by 1 

DOWN 



 

- decreases the digit by 1 

RESET

 + 



  

- shifts the decimal point 

RECALL

 

- aborts the edit process 

SET

 

- saves data and exits 

5.4.6

 

 



 

DEAD  BAND  -

  Press  the 

SET

  button  to  display  the  current  DEAD  BAND  value  and  use  the 

buttons to set the required value. Press 

RECALL

 to exit up one level without making a change or 

press 

SET

 to save the change. Edit the value using the buttons as shown in 



 above. 

5.5 

 



 

Same as 



 but for 

ALARM 2

5.6 

 



 

Used  to  set or  show  the  Analog Output  (Option) parameters.    This  menu  item  has  a  number  of  sub  items.    Once  selected 
with the 

SET

 button, the instrument will display its current setting.  To exit back to  the main menu without changing the 

function, press the 

RECALL

 button.  If you wish to change the function, you can view the options using the 

UP 



 

button.  

The available options are shown below.  When the desired function is displayed, press the 

SET

 button.  The unit will return 

to the last menu level. 

5.6.1

 

 



 

ZERO SCALE  - 

Sets the Zero Scale value  for the Analog output. Press the 

SET

 button and use 

the  buttons  to  edit  the  value  as  per 



  above.    Press 

RECALL

  to  exit  up  one  level  without 

making a change or press 

SET

 to save the change. 

5.6.2

 

 



 

FULL SCALE - 

Sets the Full Scale value for the Analog output. Press the 

SET

 button and use the 

buttons to edit the value as per 



 above. Press 

RECALL

 to exit up one level without making a 

change or press 

SET

 to save the change. 

5.6.3

 

 



 

DIAGNOSTIC  - 

Sets  the  analog  output  to  a  preset  value  for  diagnostic  purposes.  Options  are 



,

 



 or 



 (Zero) scale. Press 

RECALL

 to exit up one level without making a change or 

press 

SET

 to save the change. 

5.7 

 



 

Sets the BAUD rate for serial communication (Option).  Press the 

SET

 button to display the current baud rate. Press the 

UP 



 

button to view the baud rate options:  



.

 - 115200, 



.

 - 57600, 



.

 - 38400, 



.

 - 19200, 

.

 - 9600, 

.

 - 4800, 

.

 – 2400.  When the desired mode is displayed, press the 

SET

 button to select or the 

RECALL

 button to ignore.  The unit 

will return to the menu.  

5.8 

 



 

Sets the IP Address for the

 Ethernet

 interface (Option). There are three sub items: 



 – IP Address, 



 – Sub Net Address, 



 – Gateway Address. These addresses are in the format 192.168.000.100. Use the buttons to edit the values as required. 

RESET

  

- changes the digit being edited to the right. Will stop at the right most digit 

RESET + 

 

- changes the digit being edited to the left. Will stop at the left most digit 

UP 



 

- increases the digit by 1 

DOWN 



 

- decreases the digit by 1 

RECALL

 

- aborts the edit process 

SET

 

- enters the sub menu item for editing and when pressed again saves data and exits 

5.9 



 

Sets the sense for the Pulse Output.  Press the 

SET

 button to change the sense of the Pulse Output and use the 

UP

 



 button 

to  select  NEGative  or  POSitive.  Press 

RECALL

  to  exit  up  one  level  without  making  a  change  or  press 

SET

  to  save  the 

change. 

5.10   



 

Sets the Display Update Rate.  Press the 

SET

 button to change the display update rate and use the 

UP

 



 button to select 

½

1

 or 

1.5

 second update rate. Press 

RECALL

 to exit up one level without making a change or press 

SET

 to save the change.  

Содержание ACT-3X

Страница 1: ...Totalizer Ratemeter User Manual and Reference Guide MONARCH INSTRUMENT 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www mona...

Страница 2: ...e personal injury or death may occur as a result 7 This instrument may not be safe for use in certain hazardous environments and serious personal injury or death could occur as a result of improper us...

Страница 3: ...4 3 2 3 UP and DOWN BUTTONS 5 3 2 4 RECALL BUTTON 5 4 0 OPERATION 5 4 1 Modes of Operation Channel 1 5 4 1 1 RPM Mode 5 4 1 2 Frequency Mode 5 4 1 3 Scale Mode Ratemeter 5 4 1 4 Single Event Capture S...

Страница 4: ...5 9 11 5 10 11 5 11 12 5 12 12 6 0 SERIAL OUTPUT 12 6 1 Data from the Serial Interface 12 6 2 Serial Commands 12 6 2 1 Run Mode Commands 12 6 2 2 Control Commands 13 7 0 SPECIFICATIONS 14 8 0 OPTIONS...

Страница 5: ...xed equipment or permanently connected If permanently connected disconnection from the supply must be possible via a customer supplied switch or circuit breaker rated at 120V or 240V dependent on loca...

Страница 6: ...ve Hot wire to the terminal marked L and the Neutral Return wire to the terminal marked N NOTE The ground connection is not required as the unit is fully isolated from the mains If the unit is dc powe...

Страница 7: ...nput is also referred to as Channel 2 CH 2 and will accept a TTL input or any signal up to 12Vdc It has a weak pull up internally and can be used with a set of potential free contacts The AUX input is...

Страница 8: ...is another input pulse It is more useful at slow speeds as it appears to be on continuously at higher inputs It gives an indication that a valid input trigger signal is present 3 1 3 MAX and MIN LEDS...

Страница 9: ...1 2 Frequency Mode In the Frequency Mode the unit displays input pulses per second or more commonly Hertz Hz This is the most basic mode of operation The range of measurement in this mode is 0 0833 t...

Страница 10: ...nding on the sense programmed It acts as a gate preventing the input signal from updating the unit 4 2 3 Single Event Capture When programmed as Single Event Capture this input acts as the second inpu...

Страница 11: ...become de energized Thus in the event of a power failure the relays will drop out by default creating the equivalent of an alarm condition 4 5 Analog AO and Current IO Output The ACT 3X has options f...

Страница 12: ...or 14 640 RPM the internal update rate is the period of the input frequency Thus the response of the alarms etc can be seen to be a function of the input Above an input of 244 Hz the alarms respond wi...

Страница 13: ...d scale factor Press RECALL to exit up one level without making a change or press SET to save the change The edit buttons function as follows RESET changes the digit being edited blinking digit UP inc...

Страница 14: ...EGative or POSitive Press the SET button to select the new setting or the RECALL button to exit without saving the settings 5 3 Sets the decimal point on the displayed reading To enter this menu item...

Страница 15: ...a change or press SET to save the change 5 6 2 FULL SCALE Sets the Full Scale value for the Analog output Press the SET button and use the buttons to edit the value as per above Press RECALL to exit u...

Страница 16: ...ent occurs Other information is sent on demand and is covered in the following section The messages are sent as standard ASCII and all messages end with a carriage return CR There is no Line feed sent...

Страница 17: ...mand Category Argument Value eg CH_1 TYPE SCALE 60 0 sets the Scale Mode Scale factor to 60 0 Command Argument eg DECPT NONE sets the Decimal Point to none Command Category Argument Action CH_1 Channe...

Страница 18: ...100 times per second Standard Gate or up to 1000 Fast Gate Dependent on input frequency Input must be measurement rate Scale Mode Scaling Computation Programmable scaling 0 0001 to 99 999 Front panel...

Страница 19: ...preadsheet Software available for download at www monarchinstrument com ROLS W Remote Optical Laser Sensor with 8 foot cable ROS W Remote Optical Sensor with 8 foot cable ROS P 25 Remote Optical Senso...

Страница 20: ...ing the circumference of the shaft you are monitoring This could also be a speed wheel tire etc The circumference x diameter 3 14159 In order to scale we need to know what we want as opposed to what w...

Страница 21: ...il the display shows and then press the SET button The display will show the current scale factor value with the right most digit flashing The UP and DOWN buttons change the flashing digit The RESET b...

Страница 22: ...an error in the placement of the sensors The tape edges won t be exactly 1 inch apart Assuming the edges were really 1 01 inches apart there would be 1 error So at 130 MPH your reading would be 128 7...

Страница 23: ...hat the device is set up for DHCP by default so it will get an IP address from your local server Once the search is complete the window will be populated as shown next The current device setting is sh...

Страница 24: ...ons to set the required value Press RECALL to exit up one level without making a change or press SET to make the change The edit buttons function as follows RESET changes the digit being edited blinki...

Отзывы: