Monacor PA-4120D Скачать руководство пользователя страница 6

6

English

Deutsch
Deutsch Seite

Français
Français Page

Italiano
Italiano Pagina

Español
Español Página

Nederlands
Nederlands Pagina

Polski
Polski Strona

Dansk
Dansk Sida

Svenska
Svenska Sidan

Suomi
Suomi Sivulta

0

10

CH 1

4 Ω

PEAK

SIG

PROT

100 V

3

4

POWER

0

10

0

10

0

10

0

10

CH 1

CH 2

CH 3

CH 4

4 Ω

PEAK

SIG

PROT

100 V

4 Ω

PEAK

SIG

PROT

100 V

2

1

 

Front panel

English
English Page

Class D PA Amplifier 

with 4 Channels

These instructions are intended for installers 
of the unit with technical knowledge of 100 V 
technology in PA applications . Please read the 
operating instructions carefully prior to opera-
tion and keep them for later reference .

1  Overview

1.1 Front panel

LED indicator; to indicate that the amplifier 
has been switched on or switched to the 
standby mode (

 “Standby” in chapter 5)

POWER switch

for each channel CH 1 to CH 4:

Level control 

LED indicators

PROT

Will light up when the protective circuit 
responds; it will light up briefly each 
time the amplifier is switched on or off 
(or switched to the standby mode*) .

PEAK

Will light up when the maximum signal 
level allowed has been reached; if the 
LED indicator lights up continuously, 
turn back the level control .

SIG

Will light up when a specific signal level 
has been reached (depending on the 
level control) .

100 V 

or 

4 Ω

The operating mode set will be in-
dicated by the LED indicator that 
lights up .

*  via a switch connected to the terminals STANDBY (7)

1.2 Rear panel

Switch to set the operating mode:
“100 V” = operation with 100 V speakers
“4 Ω”  =  operation with low-impedance 

speakers 

Power cable for connection to 230 V/ 50 Hz

Plug-in screw terminals STANDBY to con-
nect a switch for the function “Switch on 

 Standby”; if 

no

 switch is connected, 

make sure that the terminals are bridged

Plug-in screw terminals MUTE to connect 
a switch for muting the amplifier

for each channel CH 1 to CH 4:

Plug-in screw terminals “100 V/ 4 Ω” to 
connect the speakers

10 

Plug-in screw terminals FAILED; can be 
used as a fault indication output for  
remote monitoring: 

 chapter 4 .2 .3

11 

Plug-in screw terminals INPUT: balanced 
input to connect a mono signal source with 
line level

2  Safety Notes

The product corresponds to all relevant direc-
tives of the EU and is therefore marked with   .

WARNING

The product uses dangerous 
mains voltage . Leave servicing 
to skilled personnel only and 
never insert anything into the 
air vents . Risk of electric shock!

In the operating mode “100 V”, there is a 
hazard of contact with a dangerous voltage 
of up to 100 V at the speaker terminals (9) . 
Always switch off the amplifier before making 
or changing any connections .

• 

The product is suitable for indoor use only . 
Protect it against dripping water, splash 
water, high air humidity and heat . The 
admissible ambient temperature range is 
0 – 40 °C . 

• 

Do not place any vessel filled with liquid on 
the product, e . g . a drinking glass .

• 

The heat generated inside the product must 
be dissipated by air circulation; never cover 
the air vents of the housing .

• 

Do not use the product and immediately 
disconnect it from the mains socket
1 . if the unit or the mains cable is visibly 

damaged

2 . if a defect might have occurred after the 

unit was dropped or suffered a similar 
accident,

3 . if malfunctions occur .
Any repairs must be made by skilled per-
sonnel only .

• 

A damaged mains cable must be replaced 
by skilled personnel only .

• 

Never pull the mains cable to disconnect the 
mains plug from the mains socket, always 
seize the plug .

• 

For cleaning only use a dry, soft cloth; never 
use water or chemicals .

• 

No guarantee claims for the product and no 
liability for any resulting personal damage 
or material damage will be accepted if the 
product is not correctly used or if it is not 
repaired in an expert way .

• 

Important for UK Customers!

The wires in this mains lead are coloured in 
accordance with the following code:
green  / yellow  =  earth
blue = neutral
brown = live

As the colours of the wires in the mains lead 
of this appliance may not correspond with 
the coloured markings identifying the termi-
nals in your plug, proceed as follows:
1 . The wire which is coloured green and yel-

low must be connected to the terminal in 
the plug which is marked with the letter 
E or by the earth symbol 

, or coloured 

green or green and yellow .

2 . The wire which is coloured blue must 

be connected to the terminal which is 
marked with the letter N or coloured 
black .

3 . The wire which is coloured brown must 

be connected to the terminal which is 
marked with the letter L or coloured red .

Warning

 – This appliance must be earthed .

If the product is to be put out of oper-
ation definitively, dispose of the prod-
uct according to local regulations .

3  Applications

This class D amplifier is specially designed for 
PA systems that use 100 V technology . How-
ever, it is also possible to use low-impedance 
speakers instead of 100 V speakers .

Via four amplifier channels, the volume 

for up to four speaker zones can be separately 
adjusted . Each channel provides a balanced 
line level input and an error message output 
for remote monitoring of the operation state 
of the channel (both connections designed as 
plug-in screw terminals) . In addition, two ex-
ternal switches can be connected: a switch to 
mute all four channels at the same time and a 
switch for the function “Switch on 

 Standby” .

4  Installation

Installation must be made by skilled personnel 
only .

4.1 Setting up the amplifier

The amplifier is designed for insertion into a 
rack (482 mm  / 19"), but it can also be set up on 
its own . In order to ensure sufficient cooling of 
the amplifier, air must always be able to flow 
freely through all air vents . 

4.1.1 Rack installation

For rack installation, 1 rack space (1 RS = 
44 .45 mm) is required . For a safe installation 
of the amplifier, lateral rails or a bottom plate 
are recommended .

The hot air given off by the amplifier must 

be dissipated from the rack; otherwise, heat 
will accumulate in the rack which may not only 
damage the amplifier but also other units in 
the rack . In case of insufficient heat dissipation, 
install a ventilation unit into the rack .

Содержание PA-4120D

Страница 1: ...CIALISTS ELECTRONICS FOR SPECIALISTS ELA Class D Verstärker mit 4 Kanälen Class D PA Amplifier with 4 Channels PA 4120D Bestell Nr Order No 1000015 POWER 0 10 0 10 0 10 0 10 CH 1 CH 2 CH 3 CH 4 4Ω PEAK SIG PROT 100V 4Ω PEAK SIG PROT 100V BEDIENUNGSANLEITUNG INSTRUCTION MANUAL ...

Страница 2: ...00 V speakers 230 V 50Hz 100 V 4Ω FAILED INPUT G CH 4 100V 4Ω FAILED INPUT G CH 3 STANDBY MUTE 100V 4Ω FAILED INPUT G CH 2 100V 4Ω FAILED INPUT G CH 1 100 V 4 Ω 100 V 4 Ω 8 Ω 8 Ω 16 Ω 16 Ω 16 Ω 16 Ω 4 Ω 4 Ω 4 Ω 4 Ω 4 Ω Gesamtimpedanz der Lautsprechergruppe Total impedance of the speaker group 4 Ω Gesamtimpedanz der Lautsprechergruppe Total impedance of the speaker group 4 Ω Gesamtimpedanz der Laut...

Страница 3: ...uenzbereich 80 16000Hz 1dB 3dB Signal Rausch Abstand 95dB Einsatztemperatur 0 40 C Stromversorgung 230V 50Hz Leistungsaufnahme max 850VA Abmessungen 483 52 320mm B H T 1HE Gewicht 5 1 kg English Specifications Rated output power RMS power 4 120W THD 0 1 at 1kHz and 1 3 rated output power Speaker outputs 100V minimum load impedance 83Ω or 4Ω Inputs sensitivity impedance connection 0 775V 20kΩ plug ...

Страница 4: ...e im Produkt entstehende Wärme muss durch Luftzirkulation abgegeben werden Decken Sie darum die Lüftungsöffnungen am Gehäuse nicht ab Benutzen Sie das Produkt nicht und ziehen Sie sofort den Netzstecker aus der Steck dose wenn 1 sichtbare Schäden am Gerät oder am Netz kabel vorhanden sind 2 nach einem Sturz oder Ähnlichem der Verdacht auf einen Defekt besteht 3 Funktionsstörungen auftreten Lassen ...

Страница 5: ... Gerät wieder ausschalten 1 Um beim ersten Einschalten eine zu hohe Anfangslautstärke zu vermeiden die Pegel regler 3 aller vier Kanäle auf null drehen 2 Den Verstärker mit dem Netzschalter POWER 2 einschalten Die LED 1 über dem Schalter leuchtet und in der LED Reihe 4 jedes Kanals zeigt die entspre chende LED 100V oder 4Ω den Be triebsmodus an Für kurze Zeit nach dem Einschalten leuchtet für jede...

Страница 6: ...it from the mains socket 1 if the unit or the mains cable is visibly damaged 2 if a defect might have occurred after the unit was dropped or suffered a similar accident 3 if malfunctions occur Any repairs must be made by skilled per sonnel only A damaged mains cable must be replaced by skilled personnel only Never pull the mains cable to disconnect the mains plug from the mains socket always seize...

Страница 7: ...for the first time set the level controls 3 of all four channels to zero to make sure that the initial volume will not be too high 2 Use the POWER switch 2 to switch on the amplifier The LED indicator 1 above the switch will light up in the LED indicator strip 4 of each channel the LED indica tor 100V or 4Ω will indicate the operating mode After switch on the LED indicator PROT for each channel wi...

Страница 8: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 2053 99 01 03 2020 ...

Отзывы: