4.3  Operation without DMX controller

Select the menu item 

 or 

 : The spot-

light will project a light beam whose colour tem-
perature and brightness depend on the settings 
of the two menu items 

 and 

 .

To set the brightness for cool white, call up 

 and set the desired value (

 = cool 

white off, 

 = maximum brightness of cool 

white) . To set the brightness for warm white, 
call up 

 and set the desired value (

 = 

warm white off, 

 = maximum brightness 

of warm white) . The brightness ratio between 
cool white and warm white will define the colour 
temperature .

4.3.1 Stroboscope

Select the menu item 

 : The spotlight will 

emit flashes of light whose brightness and colour 
temperature depend on the settings of the two 
menu items 

 and 

 (see above) .

To set the flash rate, call up 

 and set the 

desired value (

 = lowest flash rate, 

 = 

highest flash rate) .

4.4  Additional menu functions

After setting the functions below, select the de-
sired operating mode again .

4.4.1 Temperature-controlled power limitation

menu item 

The spotlight is equipped with a power limita-
tion function . It will protect the spotlight against 
overheating when the internal temperature is 
too high . When this function has been activated 
(

), the power consumption of the LED will 

be reduced to 50 % when the internal temper-
ature reaches approximately 80 °C . The power 
consumption will rise to 100 % again when the 
temperature has dropped sufficiently .
In the 5-channel DMX mode, the function can be 
deactivated or activated via channel 5 (

 chap-

ter 4 .2 .2) .

4.4.2 LED response time

menu item 

When 

 has been selected, the LED will im-

mediately respond when the brightness setting 
is changed . To simulate the slow response of 

a conventional lamp, select the desired setting 
from the four settings 

 (slightly slow re-

sponse) … 

 (slowest response) .

In the 5-channel DMX mode, the response time 
of the LED is adjusted via channel 5 (

 chap-

ter 4 .2 .2) .

4.5  Indication of the internal temperature

To indicate the internal temperature of the spot-
light on the display, keep the button ENTER 
pressed for 5 seconds . To return to the previous 
indication on the display, press the button MENU 
or ENTER .

Example:

 

 

indication 

 = internal temperature of 50 °C

5  Specifications

Data protocol:  .  .  .  .  .  .  .  .  .  DMX 512
Number of
DMX channels:  .  .  .  .  .  .  .  .  3 or 5 (selectable)
Light source:  .  .  .  .  .  .  .  .  .  .  white COB LED
  Power consumption:  .  .  .  100 W
  Beam angle:  .  .  .  .  .  .  .  .  .  60°
  Colour temperature:  .  .  .  adjustable 

3200 – 6500 K

Stroboscope frequency:   .  20 Hz  max . 
DMX connections:   .  .  .  .  .  XLR, 3 poles
  Pin configuration:  .  .  .  .  .  pin 1 = ground 

pin 2 = DMX− 
pin 3 = DMX+

Ambient temperature:   .  .  0 – 40 °C
Power supply:  .  .  .  .  .  .  .  .  .  230 V / 50 Hz
Power consumption:  .  .  .  .  160 VA  max .
Dimensions W × H × D
(without bracket):  .  .  .  .  .  .  150 × 220 × 245 mm
Weight:   .  .  .  .  .  .  .  .  .  .  .  .  .  1 .5 kg

Subject to technical modification .

All rights reserved by MONACOR 

®

 INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may 

be reproduced in any form or by any means for any commercial use.

Содержание Leuchtkraft 1000177

Страница 1: ...LEUCHTKRAFT PARC 100E CTW Bestell Nr Order No 1000177 BEDIENUNGSANLEITUNG INSTRUCTION MANUAL DMX LED Scheinwerfer DMX LED Spotlight...

Страница 2: ...Helligkeit Kaltwei Operation without DMX controller brightness of cool white Betrieb ohne DMX Steuerger t Helligkeit Warmwei Operation without DMX controller brightness of warm white Betrieb ohne DMX...

Страница 3: ...3 Deutsch Seite 4 English Page 8...

Страница 4: ...das Produkt nicht und ziehen Sie sofort den Netzstecker aus der Steckdose wenn 1 sichtbare Sch den am Ger t oder am Netz kabel vorhanden sind 2 nach einem Sturz oder hnlichem der Ver dacht auf einen D...

Страница 5: ...mit dem DMX Eingang des ersten DMX gesteuerten Ger ts verbinden 2 Den DMX Ausgang des ersten DMX gesteuer ten Ger ts mit dem DMX Eingang des zweiten DMX gesteuerten Ger ts verbinden Dessen Ausgang mi...

Страница 6: ...eordnet Beispiel Ist im 5 Kanal Modus die Startadresse 5 eingestellt sind die Kan le 1 bis 5 den Adressen 5 bis 9 zugeordnet Die Adresse 10 ist dann die n chstm gliche freie Startadresse f r das folge...

Страница 7: ...ntemperatur ca 80 C erreicht Die Leistungs aufnahme steigt wieder auf 100 wenn die Temperatur ausreichend abgesunken ist Im 5 Kanal DMX Betrieb l sst sich die Funktion ber den 5 Kanal aus und einschal...

Страница 8: ...d after the unit was dropped or suffered a similar accident 3 if malfunctions occur Any repairs must be carried out by specialists A damaged mains cable must be replaced by skilled personnel only Neve...

Страница 9: ...ded to insert a DMX level matching amplifier e g SR 103DMX 1 Connect the DMX output of the controller to the DMX input of the first DMX controlled unit 2 Connect the DMX output of the first DMX contro...

Страница 10: ...h start ad dress 5 the channels 1 to 5 are assigned to the addresses 5 to 9 Address 10 is the next possible start address available for the following DMX con trolled unit It will now be possible to co...

Страница 11: ...power consumption will rise to 100 again when the temperature has dropped sufficiently In the 5 channel DMX mode the function can be deactivated or activated via channel 5 chap ter 4 2 2 4 4 2 LED res...

Страница 12: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 2078 99 02 02 2021...

Отзывы: