background image

M   LLET

Füllstandtechnik

GmbH

1.4

Dimensions

Operating instructions

1. Description

1.1 Intended use

The level indicator observes the filling level as a limit switch in silos
and vessels. It can be used as full, demand and empty indicator for
dusty and powdery, granulated and grainy bulk goods with a max.
grain size up to 30 mm and with a bulk density of 0.3 t/m³ ... 2.5 t/m³.

1.2 Function

The bulk goods presses with its weight against the double
membrane. A tappet directly transfers the pressure from the
membranes to the switch. When the bulk goods are decreasing,
pressure is taken off the membranes and the switch will be
interconnected.

1.3 Technical data

Manufacturer

MOLLET

Füllstandtechnik GmbH

Address

Industriepark RIO 103
74706 Osterburken

Name

Membrane level indicator

Type

MFD

Temperature range

-20 °C ... +70 °C

Signal contact

change-over contact, potentialfree

Capacity of the contact

4 A / 250 V AC

Switching voltage

24 V ... 250 V AC

or 12 V ... 125 V DC

Sensitivity

60 g ... 200 g adjustable

Response delay

none

Cable entry

Cable gland M20x1.5

Cable connection

Scrwe M4

Type of protection

IP65

   

acc. to DIN EN 60529

Overpressure safety

up to 5 bar

Weight

0.73 kg

Maintenance

none

Mounting position

any position

IP

04/13

MFD-BA 

  ©

 by MOLLET

        

      

01

Safety instructions

1.

The installation, 

2.

Comply with the local and statutory rules and regulations and/or the VDE 0100.

3.

Take notice of the temperature specifications at the data plate.

4.

A fuse (with max. 4A) has to be connected in series to the voltage supply.

5.

Protect the signal contact from voltage peaks when inductive loads are connected.

6.

The device may put into operation if it is closed, only.

7.

Switch off the power supply, before opening the device. (touchdangerous voltage)

initial operation and maintenance may be done by a qualified expert with electrical know-how only.

Read and follow these safety instructions first and take notice of the operating instructions.

MOLLET   D-74706 Osterburken  Tel.  +49  6291 6440-0  Fax  +49  6291 9846         Operating instructions

T

a

Contact

top

002-0202

154

142

7

Ø 128

Ø 124

3.5

25

49

M20x1.5

1.5 Materials

Housing

GFK  (glass-fibre reinforced plastics)

Type

Membrane Mounting ring

MFD-NN

= NBR

Steel, galvanized

MFD-VN

= VITON

Steel, galvanized

MFD-NE

= NBR

Stainless steel 1.4301 / 304

MFD-VE

= VITON

Stainless steel 1.4301 / 304

Membrane level indicator

MFD

Отзывы: