background image

Hand Crimp Tool for SL™ Crimp Terminals 

Doc No: ATS-011010209 

Release Date: 07-16-94 

UNCONTROLLED COPY

 

Page 4 of 5 

Revision: D 

Revision Date: 04-16-08 

 

 

How to Adjust Tool Crimp Force 

(See Figure 4) 

 
It may be necessary over the life of the tool to adjust tool-crimping force.  Listed below are the steps required to 
adjust the crimping force of the hand tool to obtain proper crimp conditions: 
 
1.

 

Remove the screw and washer.  Located over the adjustment ring. 

2.

 

Lift the adjusting ring slightly, off of the locating pin. 

3.

 

Turn the adjusting ring in the desired direction (L= less force, T= more force) to increase or decrease crimp 
pressure. 

4.

 

Press the adjusting wheel flat against the tool and engage the locking pin. 

5.

 

Replace the washer and screw. 

6.

 

Check the crimp specifications after tool crimp force is adjusted. 

 

Warranty 

 
This tool is for electrical terminal crimping purposes only.  This tool is made of the best quality materials.  All vital 
components are long life tested.  All tools are warranted to be free of manufacturing defects for a period of

 30 

days.  

Should such a defect occur, we would exchange the tool free of charge.  This will not be applicable to 

altered, misused, or damaged tools.  This tool is designed for hand use only. Any clamping, fixturing, or use of 
handle extensions voids this warranty. 
 
Hand held crimping tools are intended for low volume, prototyping, or repair requirements only. 
 

Caution:

 Repetitive use of this tool should be avoided. 

 

Notes: 

 
1.

 

This tool should only be used for the terminals and wire gauges specified on this sheet. 

2.

 

This tool is not adjustable for crimp height, however crimp force is adjustable (See instructions above).  
Variations in tools, terminals, wire stranding and insulation types may affect crimp height. 

3.

 

This tool is intended for standard conductor sizes.  It may not give a good insulation crimp support for all 
insulation sizes. 

4.

 

Molex does not repair hand tools (see warranty above).  The replacement parts listed are the only parts 
available for repair.  If the handles or crimp tooling is damaged or worn, a new tool must be purchased. 

5.

 

Pull force should be used as the final criteria for an acceptable crimp.  Pull force is measured with no 
influence from the insulation crimp.  The insulation should be stripped long (1/2 in.) so the insulation grips 
on the terminal do not grip the wire insulation or the conductor.  Refer to Molex Quality Crimping 
Handbook 63800-0029 for additional information on crimping and crimp testing. 

6.

 

Molex does not certify crimp hand tools. 

 

CAUTION

:  Molex crimp specifications are valid only when used with Molex terminals, applicators and 

tooling. 

 

Содержание CR60930B

Страница 1: ...87 8030 24 26 30 0 20 0 13 0 05 1 09 1 65 1 01 1 52 043 065 040 060 2 54 3 17 100 125 50088 8100 50088 8128 50088 8000 50088 8060 50088 8114 50088 8160 50088 8014 50088 8099 50088 50088 8028 24 26 30 0 20 0 13 0 05 1 09 1 65 1 01 1 52 043 065 040 060 2 54 3 17 100 125 16 02 0108 40 08 0872 16 02 0077 16 02 0105 16 02 0109 16 02 0078 40 08 0871 70021 16 02 0110 16 02 0091 24 26 30 0 20 0 13 0 05 1 ...

Страница 2: ... 11 044 17 8 4 00 X 28 0 08 0 56 0 66 022 026 1 11 044 11 1 2 50 X 50087 30 0 05 0 56 0 66 022 026 1 11 044 6 7 1 50 X 24 0 02 0 66 0 76 026 030 1 23 048 28 9 6 50 X 26 0 12 0 56 0 66 022 026 1 11 044 17 8 4 00 X 28 0 08 0 56 0 66 022 026 1 11 044 11 1 2 50 X 50088 30 0 05 0 56 0 66 022 026 1 11 044 6 7 1 50 X 24 0 02 0 66 0 76 026 030 1 23 048 28 9 6 50 X 26 0 12 0 56 0 66 022 026 1 11 044 17 8 4...

Страница 3: ...the conductor and insulation grips visually 4 Close the tool until the ratchet releases See Figure 4 5 Lift the locator blade or wire stop up 6 Carefully remove the crimped terminal Maintenance It is recommended that each operator of the tool be made aware of and responsible for the following maintenance steps 1 Remove dust moisture and other contaminants with a clean brush or soft lint free cloth...

Страница 4: ...gned for hand use only Any clamping fixturing or use of handle extensions voids this warranty Hand held crimping tools are intended for low volume prototyping or repair requirements only Caution Repetitive use of this tool should be avoided Notes 1 This tool should only be used for the terminals and wire gauges specified on this sheet 2 This tool is not adjustable for crimp height however crimp fo...

Страница 5: ...g Main 1 3 11 11 0320 Spring Ratchet 1 Not all tools are equipped with a locator or locator blade Americas Headquarters Lisle Illinois 60532 U S A 1 800 78MOLEX amerinfo molex com Far East North Headquarters Yamato Kanagawa Japan 81 462 65 2324 feninfo molex com Far East South Headquarters Jurong Singapore 65 6 268 6868 fesinfo molex com European Headquarters Munich Germany 49 89 413092 0 eurinfo ...

Отзывы: