HarshIO 300 ePN
48
IP67 Digital I/O Modules for PROFINET IO
Configure HarshIO module parameters
To open the module parameters dialog box, select the head module (slot 1), double click and select the
Parameters
tab.
IO Configuration Group (available only with HarshIO user M8 configurable version - TBDEP-8YYP-
D84 and M12 configurable version
– TBDEP-4YYP-D8U)
For each of the 8 channels, you can define the digital port as
o
Input
o
Output
o
Input/Output
also called
“Universal” means that the digital channel is
automatically acting as
Input or Output
depending if the controller is reading or writing into the corresponding channel
Input filter
Define the input filter delay in a range of 0.5 to 3ms. The parameter applies on all the inputs channels.
Fig. F: HarshIO module parameters