64001-5900 Hand Crimp Tool 

Doc No. ATS-640015900 

Release Date: 11-22-05 

UNCONTROLLED 

COPY

 

Page 8 of 8 

Revision: B 

Revision Date: 12-06-06 

 
 
 
 
 
 

Certificate of Calibration 

 
Tool Order Number __________________ 
 
Tool Eng. Number ___________________ 
 
Tool Revision 

___________________ 

 
Serial Number  ___________________ 
 
Date of Manufacture__________________ 
 

Handle Load Range at 1 inch from the Tips =______________ 

 

Actual =_____________ 

 
Pin Gauge of Conductor Nest/Nests or Slug height if the nest is 

the “F” Crimp style. 

 
 
Range Conductor Nest # 1 = ____________-- Actual = ______________ 
 
 
 
 
Technician ______________ 
 
Date of Calibration ______________ 
 
Calibration should be done every 5,000 cycles or 3 months. 
 
Tools should be lubricated during this operation. 
 
 

Americas Headquarters 

Lisle, Illinois 60532 U.S.A. 
1-800-78MOLEX 
[email protected] 
 

Far East North Headquarters 

Yamato, Kanagawa, Japan 
81-462-65-2324 
[email protected] 
 

Far East South Headquarters 

Jurong, Singapore 
65-6-268-6868 
[email protected] 
 

European Headquarters 

Munich, Germany 
49-89-413092-0 
[email protected] 
 

Corporate Headquarters 

2222 Wellington Ct. 
Lisle, IL 60532 U.S.A. 
630-969-4550 
Fax: 630-969-1352 

Visit our Web site at http://www.molex.com 

 

Содержание 64001-5900

Страница 1: ... using the wrong pocket SCOPE Products AviKrimp Male Quick Disconnect Terminal for 10 12 AWG Testing Mechanical The tensile test or pull test is a means of evaluating the mechanical properties of the crimped connections The following charts show the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate the t...

Страница 2: ... 2 3 Insert the properly stripped wire into the terminal barrel See Figure 2 and 3 The wires end should butt against the wire stop position of the locator Cycle the tool Note The tamper proof ratchet action will not release the tool until it has been fully closed 4 Lift the locator blade or wire stop and remove the crimped terminal Inspect for proper crimp location and check for insulation closure...

Страница 3: ...te 11 22 05 UNCONTROLLED COPY Page 3 of 8 Revision B Revision Date 12 06 06 Note Whenever crimping without the locator make sure the seam of the terminal is oriented up or down in the tool if using unbrazed product as this will provide higher pull force values ...

Страница 4: ...l Do not oil excessively The 64001 5900 was engineered for durability but like any fine piece of equipment it needs cleaning and lubrication for a maximum service life of trouble free crimping A light oil such as 30 weight automotive oil used at the oil points shown in Figure 4 every 5 000 crimps or 3 months will significantly enhance the tool life and ensure a stable calibration 4 When tool is no...

Страница 5: ... this tool pin gauge measurements should be taken in each conductor nest and compared to this chart The tool should be lubricated prior to recalibration to ensure consistent measurements Handle preload is factory set to 25 45 LBS See How to Adjust Tool Preload see Figure 5 to recalibrate Nest Color Code Wire Range X Dimension Conductor Crimp Crimp Inspection Marking AWG mm Mean Go No Go Yellow 10 ...

Страница 6: ...imp Tool Doc No ATS 640015900 Release Date 11 22 05 UNCONTROLLED COPY Page 6 of 8 Revision B Revision Date 12 06 06 CAUTION Molex crimp specifications are valid only when used with Molex terminals applicators and tooling ...

Страница 7: ...R REPAIR ONLY MAIN SPRING SHOWN 2 PARTS LIST Item Order No Description Quantity 64001 5900 Hand Crimp Tool Figure 6 1 64000 0076 Repair Kit Springs Pins and E Rings 1 2 63810 0000 Handle 1 3 64001 4875 Locator Assembly 1 4 64001 5970 Tooling Kit 1 Tooling Kit Only 5 64001 5904 Conductor Punch 1 6 64001 5905 Conductor Anvil 1 7 64001 4804 Insulation Punch 1 8 64001 4803 Insulation Anvil 1 9 N A 4 m...

Страница 8: ...est is the F Crimp style Range Conductor Nest 1 ____________ Actual ______________ Technician ______________ Date of Calibration ______________ Calibration should be done every 5 000 cycles or 3 months Tools should be lubricated during this operation ericas Headquarters Illinois 60532 U S A 0 78MOLEX rinfo molex com Far East North Headquarters Yamato Kanagawa Japan 81 462 65 2324 feninfo molex com...

Отзывы: