Auto Grip Pull Tester
Doc No: TM-638019100
Release Date: 08-10-09
UNCONTROLLED COPY
Page 13 of 20
Revision: E
Revision Date: 03-19-21
5.
Setting Lock
Prevents gauge setting from being changed.
1.
While pressing and holding the Info button, press and
release the ON/OFF button to turn on the gauge.
Continue to hold the Info button until the Setup Menu
appears.
2.
Press Down Arrow to highlight Setting Lock and press
Right Arrow to select.
3.
Use Up Arrow or Down Arrow to select ON or OFF,
then press Right Arrow to enter the selection.
4.
Press Left Arrow twice to exit the menu and return to
measuring mode.
See Figure 2-10 for menu navigation.
2.3
Installation
See Figure 2-11
1.
Place the Auto grip Pull Tester securely on a
stable work surface.
2.
To adjust clearance between the two wire
gripping fixtures if necessary, loosen the cap
screw on the display module mounting bracket.
Adjust the position and the retighten the cap
screw.
3.
To remove the grip, remove the black retaining
grommet near the end of the measuring shaft
and slide the grip up and off. Installation is the
reverse of removal.
4.
Connect the appropriate AC adapter (120 or 230
VAC included) to the display module and plug it
into an AC outlet or use the internal
rechargeable battery.
2.4
General Operation
See Figure 2-12
1.
Press the ON/OFF button to turn on the display module.
2.
If using the ring wire terminal grip, turn the turret to select an appropriate aperture and
bring the hand lever forward. See Figure A.
3.
Insert the sample so that the wire terminal is held in place by the grip. If necessary, press
the ZERO button to reset. See Figure B.
4.
Thread the wire between the gripper and the cylinder, which is attached to the end of the
hand lever. See Figure C.
5.
Slowly pull the hand lever back to automatically grip the wire and pull off the terminal. See
Figure D.
Note: Pull the lever slowly and steadily to ensure consistent readings.
6.
Read the result from the display module and press the ZERO button to reset for the next
test.