5.7.3 Install Thermocouple onto Nozzle Body (Optional)
1. Insert the thermocouple into the thermocouple hole on nozzle body until it
bottoms out.
2. Slide front heater onto the nozzle body and line up the slot on the heater
with thermocouple.
3. Bend the thermocouple 180 degrees, and then install the retainer clip.
5-14
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.