9.15 Injection Nozzle Replacement
WARNING
The injection nozzle area should be kept clean of debris, dust and plastic.
1. Clean the nozzle and barrel area. Remove any plastic residue, using soft
brass tools only.
2. Remove the nozzle tip and clean plastic from the nozzle opening and
inner cone.
3. Apply anti-seize compound to the nozzle tip threads and reinstall the
nozzle tip. See “Other Torque Specifications” on page 9-2.
Nozzle tip
NOTE
Because of variations between nozzles, it is recommended that any time
a nozzle is changed, the adapter plate is realigned as described in ”9.14
Adapter Plate Removal and Installation”.
9.16 Nozzle Protrusion Adjustment - Toggle Link
Models
9.16.1 Introduction
WARNING
This procedure must be done with the barrel at operating temperature.
Wear appropriate personal protective equipment. Setting the nozzle
protrusion when the barrel is cold may cause damage to the carriage
linkages. This damage is not covered under warranty.
CAUTION
The nozzle should not touch the mold during installation before the adapter
plate bolts are tight. If the nozzle touches the mold during installation
damage to the system may occur. This damage is not covered under
warranty. Before mounting the E-Multi injection unit, move the carriage back
far enough to prevent the nozzle from touching the mold during installation.
CAUTION
9-13
MAINTENANCE
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.