3.16.5 Vertical Orientation with One Lifting Machine
WARNING
Do not leave the E-Multi injection unit standing vertically without support.
This is dangerous and can result in serious injury if the unit falls over.
CAUTION
Slowly lift to avoid any slipping of the E-Multi. injection unit. Keep the hook
over the E-Multi to avoid tipping.
CAUTION
It is preferred to use two lifting machines to raise the E-Multi injection unit to a
vertical position. Use this procedure if only one lifting machine is available.
1. Remove any slings from the lower / adapter plate position.
2. Attach the slings from the lifting bar to the lifting machine. Ensure the
slings are not twisted or kinked.
3. Raise the E-Multi injection unit very slowly, keeping the lifting machine
centered over the unit.
4. Move the lifting machine up and forward (towards the barrel end of the
E-Multi injection unit), keeping the lifting machine centered over the unit.
3-29
SAFETY
E-Multi User Manual
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.