11-2
Dura+ User Manual
MAINTENANCE PROCEDURES
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
11.2 Terminal End Removal
CAUTION
Care must be taken when removing the element sleeve to avoid damage to
the ceramic sleeve or terminal nut.
CAUTION
1. Nozzle flange
2. Ceramic insert
3. Ceramic sleeves
4. Seal
5. Element sleeve
1
2
3
4
5
Figure 11-1 Nozzle terminal assembly
1. If the terminal end is covered with plastic, warm the terminal end prior to
removing the element sleeve.
2. Grip the element sleeve at the threaded area and turn counter clockwise.
If the wires rotate with the sleeve, damage may result.
3. Remove the seal.
4. Remove the set screw from the ceramic sleeve.