Function Blocks
28
02/02 AWB27-1300-GB
Selecting the function blocks
Install both the parameter function blocks in the form of a
POU file (.POE) as well as the library file (.LIB) containing the
dial-up and telecontrol function blocks. A library file is
provided for every PLC type. After installation no other
measures are required for the library files.
Example
For example, to incorporate a universal function block with
four communication channels for a PS4-300 in synchronous
mode with the ZB4-501-TC2 telecontrol module, the
following programs in the table must be installed:
• FB file: TCMT1zU2.POE
• Library file: TCM_TD_3.LIB
After the installation you can integrate the function blocks in
your user program (
page 30). Remember that it must be
called in each program cycle.
Code/data size, cycle time requirements
The specifications apply to the example programs with the
default data array sizes in a passive state. With an active
data channel this time requirement will change according to
the service concerned and can therefore only be determined
in the overall application.
Module
name
Code size [Byte]
Data size [Byte]
Subor-
dinate
FBs
In-
stan-
ces
Cycle time [ms]
200
300
400
200
300
400
200
300 400
TCMT1zB0 42436 47786 50549 4795 5221 5347 12
33
approx.
18
2.1
2.1
TCMT1zU0 52000 61824 63876 5106 5902 6036 17
40
approx.
19
2.1
2.1
TCMT1zU2 55552 65816 68466 5552 6394 6674 17
42
approx.
21
2.2
2.2
TCMT1zU5 –
68908 74204 –
8872 9362 17
42
–
2.9
2.9