B
A
C
D
E
F
G
SER
VICE
55
S
Service Manual
IMPORTANT:
•
This appliance must be serviced every 12 months.
•
Any service operation should be carried out only by a suitably qualified and trained
person.
•
Gas and electricity supply MUST be isolated before any service operation is carried
out on this appliance.
•
This manual should be left with the appliance.
•
Only use
Escea approved
spare parts.
•
Escea Spare parts are available from an Escea Distributor or Retailer
•
DO NOT MODIFY THIS APPLIANCE.
S1 Annual Service Procedure
□
Isolate power and gas supply to fire.
□
Remove glass and clean inside of glass.
□
Remove fuel bed and brush off any soot.
□
Clean electrode and pilot hood of any carbon build up and ensure correct gaps
between electrode and pilot hood
□
Remove burners and blow compressed air through the burner ports.
□
Remove jets and clean injector hole with solvent.
□
Vacuum any dust from the cavity that houses the fan and from the underside of the
fire box around the valve and solenoids.
□
Test all joints for gas tightness.
□
Reassemble heater and check that operating pressure is correct.
□
Check glass sealing tape and replace if necessary.
□
Check to make sure that flue system is intact and not in any way blocked.
□
Trial heater with several start/stop cycles. Trial fan-boost, effect only, and
thermostat modes to ensure that all modes function correctly.
To access the product data plate, first remove the fireplace glass, any fuelbed media, the burners
and the firebox base. The data plate is located underneath the controls tray (step 1 of section “E4