C
Installing the Flue
C1 Flue Configuration (If less than 8m flue length is required)
If your flue system is less than 8m long (as shown in diagrams below), then a simple aluminium flexible
flue is required. If you wish to install a longer flue run, please contact the Escea Architectural Advisory
Team.
Horizontally Terminated:
Utilises the Escea horizontal power flue enclosure kit.
The horizontal offset of the terminal can be any amount up to the total flue length listed below. Please
consult with Escea’s technical staff if your intended flue configuration falls outside of the bounds of
the flue configurations shown below.
Note: When flueing above the fire, the pipe must slope towards fire - NOT towards the terminal. Also when
flueing below the fire, the pipe must slope towards the terminal - NOT towards the fire.
X
Y
X
+
Y
Maximum = 8m
Y
Maximum = 1.5m
Y
Minimum = 0m
X
Maximum = 8m
X
Minimum = 0m
X
+
Y
Minimum = 1.2m
8m MAX
Y
X
X + Y = 8m MAX
= 1.2m MIN
1.2m Co-axial Flue