background image

The HiRes Video Company

EN

MX-232-IO-Box: Quick Install

www

.mobotix.com

HiRes Video Innovations

The German company MOBOTIX AG is known as the leading pioneer in network camera technology and its 
decentralized concept has made high-resolution video systems cost-efficient.

MOBOTIX AG • D-67722 Langmeil • Tel: +49 6302 9816-0 • Fax: +49 6302 9816-190 • [email protected] 

Weatherproof Signal Input/

Output and RS232

•  2 self-powered inputs for connecting sensors
•  2 outputs: 1 powered output, 1 isolated relay output (can 

be switched to second powered output)

•  RS232 interface when using USB cable to connect to camera*

Connection of external sensors and switching of 

external devices via MOBOTIX cameras; RS232 

interface, connection to camera using USB or 

MxBus

MX-OPT

-RS1-EXT

31.321_EN_V2_01/2014

Options for Connecting to Cameras

Function

Option 1 – USB

Option 2 – MxBus

2 signal inputs, self-powered

1 powered output 12 V

1 isolated relay output 

(can be switched to powered output 12 V)

RS232 interface

Connecting additional MxBus devices to MX-232-IO-Box

Length of the connection to the camera

0,5/2/5 m (1.6/6.6/16.4 ft)*

Max. 50 m/55 yd

Technical Specifications

Option 1 – USB

Option 2 – MxBus

Interface to camera

USB

MxBus

Inputs

2 galvanically separated inputs (AC/DC, self-powered, up to 50 V)

Output Out1

Isolated relay output (AC/DC, up to 50 V/60 W/2 A) 

With jumper J1

: Powered output 12 V, max. cable length 50 m (55 yd) 

(see 

«Changing the Mode of Output Out1»)

Output Out2

Powered output 12 V, max. cable length 50 m/55 yd

Total output rating

400 mW

500 mW

RS232 interface

Rx, Tx, RTS, CTS, GND, 

max. 115 kbaud

Cross-sectional diameters 

of wires at the terminals

Minimum: 0.14 mm² (AWG 26)

Maximum: 0.5 mm² (AWG 20)

Protection class

IP65 (DIN EN 60529)

Operating temperature

–30 to +60°C/–22 to +140°F (DIN EN 50155)

Power supply

USB

MxBus

Power consumption

Typically 1 W

USB Cables for Connection to Camera*

MX-CBL-MU-STR-05/2/5 

(straight/straight)

MX-CBL-MU-EN-STR-05/2/5 

(angled/straight)

MX-CBL-MU-EN-PG-STR-05/2/5 

(angled/straight)

MOBOTIX USB 

cable 0.5/2/5 m 

(1.6/6.6/16.4 ft) 

(order separately!)

MOBOTIX cameras

D14/D15, 

S14/S15

M24/M25, Q24/Q25

, T24/T25

D24/D

25

*Only use MOBOTIX USB cables! USB cables are not part of the delivery and are to be ordered separately!

Options for Connecting to Camera: 

USB

 

or

 

MxBus

Option 1: MOBOTIX USB cable to the 

camera (0,5/2/5 m (1.6/6.6/16.4 ft))

MOBOTIX MX-232-IO-Box

 

MX-OPT-RS1-EXT

MOBOTIX D15Di DualDome

 

MX-D15Di-Sec-D22D22

Option 2: 2-wire MxBus wiring to 

camera (max. 50 m/55 yd)

*Only use MOBOTIX USB cables! USB cables are not part of the delivery and are to be ordered separately!

Caution

One MX-232-IO-Box must not 

be connected to one camera 

via USB 

and MxBus at the 

same time!
It is likewise disallowed to 

connect one MX-232-IO-Box 

to several cameras!

Note

If you would like to use twice 

the number of signal inputs 

and outputs, you can attach 

two MX-232-IO-Box modules 

to one camera, one via USB 

and one via MxBus!

Connection of Peripheral Devices (Examples)

MOBOTIX MX-232-IO-Box

 

MX-OPT-RS1-EXT

Window sensors

Door sensors

Gate

Lights

RS232 connection 

(only when connecting to 

camera via USB cable*)

Pan/Tilt head

Max. 10 m/11 yd

Max. 50 m/55 yd

Weather Station

Relay

(e.g. Eltako 

ER12-002-UC)

Block Diagram of the MX-232-IO-Box

Changing the Mode of Output Out1

In order to use output 

Out1

 as powered output, you need to 

stick the jumper on the jumper pins 

J1

 at the right as shown in 

the figure. The other jumper will be used in the future and must 

not

 be used at present. When connecting, use the terminals 

Out1 A

 and 

Out2 –

Please note that the total output rating of the MX-232-IO-Box is 
split between the two powered outputs in this mode (see 

«Technical 

Specifications»). In this mode, the max. cable length for 

Out1

 is 

also 50 m (55 yd).

Output Out1: 

Operating mode can switched to 

"powered output" using the supplied 

jumper J1!

Jumper 

J2

 for future 

extensions – 

do not

 use!

J2

J1

Weatherproof (IP65)

–30 to +60°C/–22 to +140°F