Mobius ActionCam Скачать руководство пользователя страница 1

Instruction Manual for the Mobius ActionCam

Description

The above picture shows the arrangement of the user operating features.
The two heat sinks can become very hot during operation. This is normal, but all the same you should 
never leave the camera turned on where the surrounding temperature exceeds ~47°C (118°F) - for 
example in a car parked in the baking sun. If you wish to use the camera in very hot conditions you 
should ensure the heat sinks are adequately cooled, for example by directing cool air onto the metal 
plates or using a ventilator to dissipate the heat away from the metal plates. High temperatures will also 
damage the internal LiPo battery. If you use your camera in very hot conditions with external power, 
for example as a dashcam, you should consider replacing the battery with a Super Capacitor pair. These 
can be purchased from most suppliers who sell the Mobius. A Super Capacitor pair enables the camera 
to correctly save the last recording when external power is removed. A fully charged Supercap has 
enough energy to keep the RTC (Real Time Clock) running for several days (about 7-10) without 
external power connected. It only takes a few minutes to fully charge the Supercap. 
►This manual does not cover replacing the internal battery or lens. If you need to do this, please refer 
to the very detailed instructions found at 

http://www.rcgroups.com/forums/showpost.php?

p=25170910&postcount=4

.

This manual assumes the camera is loaded with the latest firmware available at the time of 

writing. Functionality may vary with earlier or later firmware versions.

Cards

 

Generally speaking you may use any micro SD, micro SDHC or Micro SDXC card with a capacity of 
up to 128GB with this camera. Larger cards are most likely also supported but not yet available. To 
avoid card compatibility problems, always use quality cards with a speed rating of Class 4. There are 
known problems with a few cards that have a higher class rating, for example some, but not all, 
Sandisk 32GB Ultra (class 10) will not work properly with earlier firmware versions. You should use 
firmware v1.17 or above with these cards. For the best compatibility use cards with a class 4 rating if 

Содержание ActionCam

Страница 1: ...r is removed A fully charged Supercap has enough energy to keep the RTC Real Time Clock running for several days about 7 10 without external power connected It only takes a few minutes to fully charge...

Страница 2: ...as clicks chirps hum and buzzing in the audio recording The following approx recording times for 1080p videos with a standard data rate are as follows 32GB Card 4 hours 30 mins 16GB Card 2 hours 15 m...

Страница 3: ...on is located on the right side above the card slot It can be pressed by carefully inserting a bent paper clip or similar instrument The Reset button should only be pressed in case the camera no longe...

Страница 4: ...ng video The Video Recording indicator see configuration must be ON for this to work Red LED remains on Camera is in Photo Mode or Playback Mode if an A V cable is connected and is on standby Red LED...

Страница 5: ...er voltage protection up to max 24 Volt If the external voltage exceeds 5V the camera will not start or charge Formatting Standard formatting tools provided by the operating system are not always reli...

Страница 6: ...o Mode 1 or 2 yellow or blue LED Start video recording and write protecting important clips Briefly press the shutter button If the recording LED has been disabled the yellow or blue LED will blink 3...

Страница 7: ...which you can enter webcam mode Method 1 Connect the camera as a removable drive see above Press the Shutter button to enter webcam mode If this is the first time you have connected the camera in WebC...

Страница 8: ...t know how to manually edit ASCII files please only use mSetup exe A SYSCFG TXT file must first be generated by the Camera The camera s parameters are self explanatory It is important not to change t...

Страница 9: ...possible to update the firmware using SD cards with a capacity greater than 32GB unless they are formatted to FAT32 The firmware update routine is a low level routine called before the exFAT file sys...

Страница 10: ...the two Data wires If a signal is found the camera assumes it is connected to a PC and recording will not be possible see below Recording when directly connected to a PC For recording video or taking...

Страница 11: ...connected This parameter should be set to Disabled when the camera is used with hand held devices in order to avoid draining the device s battery Audio Volume When the volume is turned OFF the sound...

Страница 12: ...e Mode button to switch to a different recording Mode Slowly pressing the Mode button 3 times will cycle back to the original Mode AEL AWBL will be automatically reset when the camera is turned off FO...

Страница 13: ...em with your cable or the PC USB drivers are corrupt DriveCleanup exe freeware may be able to fix USB corruption problems Q When the camera is connected to the PC and then turned on I can take picture...

Страница 14: ...ble is not connected properly or the lens module is damaged Q The camera does not react The green LED may be on or off A The firmware may have entered a continuous loop or the battery may be discharge...

Страница 15: ...icro SD cards with a class rating of 4 or above Low quality cards can draw excessive current which may result in electrical noise in the recording Q When I update the firmware the blue LED remains on...

Отзывы: