MOBILTEX® DATA LTD.
TITLE:
Installation and Operating Instructions
Calgary, Alberta
DOCUMENT NO.:
SPI1-MAN-001
SHEET:
29 of 57
REV:
1.14
UNIT HEALTH
V1: 02.50 V4: 03.35
V2: 04.97 V5: 12.05
V3: 03.36 V6: 03.00
V1= smart relay detect voltage (varies from 0 to 2.5V
depending on relay)
V2= +5V internal supply
V3= +3.3V internal supply
V4= GPS power supply, nominally 3.3V
V5= relay drive voltage, nominally 6V or 12V
V6 = GPS antenna voltage, nominally 3V
BATTERY MONITOR
V: 6.591V I:+0.803A
MODE: CHG(S) AGE: 00
CAP: 100% TEMP:-20C
V field indicates the internal battery voltage.
I field indicates the current flowing to/from the battery.
Negative indicates discharge.
STATUS field indicates charging/discharging. Letter in
parenthesis indicates fast (F) or slow (S) charge.
CAP field indicates current charge level in battery.
TEMP field shows the current temperature inside the SPI1.
AGE indicates how long the SPI1 internal battery has been
in service.
DATALOGGER STATUS
AC: 025.263VRMS
DC:+052.392V FILT: 0
ACTIVE: YES RNG: 60V
AC field indicates the last measured AC voltage level on
the datalogger. Measurements are taken only when a
datalogger schedule is active.
DC field indicates the last measured DC voltage level on
the datalogger.
The FILT field indicates whether the datalogger digital
60Hz suppression filter is active or not. A one in the field
indicates that the filter is active.
ACTIVE field indicates whether the datalogger is
currently taking measurements.
RNG field shows the current meter range for the
datalogger input.
*Datalogger Status screen only available on SDL1
equipped devices.
Figure 27 corTalk® Portable Interrupter Scheduler Menu Page 1