Mobeye CMVXI-R Скачать руководство пользователя страница 19

18 

7.  PROGRAMMING WHEN USING OWN SIM CARD 

Using  your  own  SIM  card  programming  proceeds  via  SMS  commands.  The  GSM 
module  requires  network  connection  during  programming.  If  the  Mobeye  Outdoor 
Detector runs entirely on batteries, it must first be put into programming mode. 

7.1  PROGRAM MODE 

The  program  mode  can  be  achieved  by  holding  the  tag  to  the  tag  reader  for  5 
seconds, until a second beep sounds. The LED in the tag reader starts flashing red 
and  green.  Alternatively,  the  program  mode  can  be  accessed  by  (re)  inserting  the 
batteries.  
 
First the GSM module establishes network connection. During this time the LED  in 
the  tag  reader  flashes  green/red.  Normally  this  takes  10-30  seconds.  Next  it  will 
shortly  flash  very  fast.  Once  the  connection  is  established  the  status  LED  starts 
flashing  1  sec.  on/1  sec.  off  (or  stays  on  continuously  in  case  the  first  telephone 
number has been configured). 
 
In  program  mode,  the  device  is  ready  to  receive  SMS  commands.  If  no  correct 
command is received for  3 minutes, the  GSM module switches off in order to save 
the batteries. The unit returns to the low power operational mode.  
 
The program mode is interrupted by keeping the tag against the tag reader for one 
second.  

7.2  PROGRAM AT LEAST ONE TELEPHONE NUMBER  

The  Mobeye  Outdoor  Detector  is  able  to  send  messages  up  to  5  telephone 
numbers. The first telephone number (TEL1) belongs to the administrator. Technical 
messages  (such  as 

battery  low

)  are  sent  to  the  administrator  only.  Without  the 

administrator

’s phone number, the Mobeye Outdoor Detector cannot function.  

When the Outdoor Detector is in initial (factory) status and the batteries are inserted 
(so  the  LED  is  flashing),  the  administrator

’s  number  is  programmed  by  calling  the 

telephone number of the Mobeye Outdoor Detector using the administrator

’s phone. 

Содержание CMVXI-R

Страница 1: ...USER MANUAL Mobeye Outdoor Detector CMVXI R SW version 5 n...

Страница 2: ...evice from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from h...

Страница 3: ...tion 10 4 6 Basics of the Mobeye Internet Portal 10 4 7 Close the Mobeye Outdoor Detector 11 4 8 Switching on off 12 4 9 Confirmation of the alarm message 12 4 10 System reset 13 5 Possible settings 1...

Страница 4: ...3 8 4 System reset 21 8 5 SMS reports when using own SIM card 22 8 6 Technical messages 23 9 Status feedback 24...

Страница 5: ...eye Internet Portal In this management environment the device is given additional functions such as online programming status and history display more options for forwarding messages and it will monit...

Страница 6: ...o influence the standard behaviour As described the Mobeye Outdoor Detector will in addition to calling in the event of an alarm send various messages to the Mobeye Internet Portal This is done via da...

Страница 7: ...ons and synchronise 5 Programming when using your own SIM card a Enter the program mode b Program the settings Steps 1 to 3 are described in sections 3 2 up to 3 3 Step 4 is described in chapter 4 Ste...

Страница 8: ...card is inserted before the batteries If you replace a SIM card first remove the batteries The settings are stored in the device memory The SIM card shall have the normal size and be suitable for 2G I...

Страница 9: ...net Portal choose activate SIM card on the Add Device screen Fill in the SIM card number This is the number written on the plastic SIM card below the barcode You can take the entire number or only the...

Страница 10: ...inuously During the first 3 minutes the GSM module remains active ready to be activated in the portal After 3 minutes a time out occurs and the GSM module switches off in order to save the batteries 4...

Страница 11: ...s missed test messages and low battery status Select a device to go to the details of a specific device Status History The status block shows values that provide information about the status of the un...

Страница 12: ...and low battery voltage To add a contact person first create it as a contact This can be done via the or in the main menu under the blue Contacts tab in the block Alarm calls from device the max 5 al...

Страница 13: ...rming After a few max 15 seconds three beeps sound which indicates that the system has fully completed the disarming process In the disarmed status the Mobeye Outdoor Detector will not send alarm noti...

Страница 14: ...settings 1 Remove the batteries and if relevant disconnect the battery pack 2 Keep an enrolled tag against the outside button while reinserting the batteries Keep it pressed for about another 5 second...

Страница 15: ...for telephone calls and or text messages from the unit This is not mandatory when using the Mobeye Internet Portal If no telephone numbers have been entered the notifications will only be sent to the...

Страница 16: ...e inactive time no new alarm message will be sent The motion detector itself has an inactive time of 2 minutes This may be extended by a longer inactive time of the Mobeye GSM module This inactive tim...

Страница 17: ...e was not received the service contacts will receive a notification The timing of the test message can be programmed Since new settings options will be synchronised after the test message setting a sp...

Страница 18: ...code and TAG A short melody confirms the correct command and indicates the tag enrolment mode Now hold a new tag to the tag reader at the bottom of the detector The detector confirms the successful en...

Страница 19: ...n 1 sec off or stays on continuously in case the first telephone number has been configured In program mode the device is ready to receive SMS commands If no correct command is received for 3 minutes...

Страница 20: ...efer to 7 1 2 Send an SMS text message with the security code and the command 3 The green LED blinks 3 times to indicate the successful configuration In case of an incorrect command the red LED flashe...

Страница 21: ...ion text NAME 20 characters Mobeye Call on off CALL ON OFF ON SMS on off SMS ON OFF ON Exit delay DELAYEXIT 0 999 sec 120 Entry delay DELAYENTRY 0 999 sec 15 Inactive time INACTIVEIN1 0 60 min 0 Alarm...

Страница 22: ...m is triggered it will send alarm notifications First an SMS text message is sent to all programmed alarm numbers followed by a phone call When you pick up the phone you will hear beeps It is possible...

Страница 23: ...uts power and batteries SMS command status request STATUS example 1111 STATUS LIST OF SETTINGS The settings can be requested by sending following SMS text message SMS command list basic settings SET S...

Страница 24: ...is added to the SMS text messages the message couldn t be sent earlier due to a SIM card failure or GSM network failure Batteries too low Module shutting down The module has shut down due to low volt...

Страница 25: ...he network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another lo...

Страница 26: ...power ca 150 A stand by max ca 500 mA Dimensions 71 x 105 x 186 mm Ambient temperature 10 C until 50 C This manual is published by Mobeye All rights the translation included are reserved Any reproduc...

Страница 27: ...26...

Страница 28: ......

Отзывы: