5.4 PRIORITY OF THE MESSAGE
Using your own SIM card this setting is not relevant. Connected to the Mobeye
Internet Portal the Mobeye Panic Button will first send an alarm notification to the
portal (to be forwarded there as an SMS and / or e-mail from there) and then call the
contacts directly from the unit. This order can be changed so that the call is first
made in order to speed up the calling. For this the priority must be on CALL. By
default, the priority is on MESSAGE (first to the portal).
5.5 INPUT TYPE
The input type defines the character of the inputs IN1 and IN2. This can be Normally
Open (NO) or Normally Closed (NC). If an input is set to "NO", the alarm will be
triggered as soon as the terminals of the input are closed. If the input is set to NC,
the alarm is triggered when the connection between the input terminals is broken.
The default input type is set to "NO".
5.6 ALARM DELAY TIME
The input delay time defines the time that the input is triggered before an alarm is
initiated. If the input returns to the non-alarm status within the delay time, no alarm is
sent. The time can be set between 0 and 999 seconds. As default, the input delay
time is set to 1 second.
5.7 ALARM REPEAT TIME
In order to emphasize the urgency of the alarm messages, all alarms can be
repeated. As long as the (external) input has not returned to the inactive status, the
textual messages (no phone calls) will be repe
ated after the ‘alarm repeat time’. The
repeat interval can be set between 0 and 24 hours. As default the alarm repeat time
is set to 4 hours.