Mounting
7.5.4.1
Single sided – wall mounting
•
The clock consists of two parts. Visible front stainless steel panel with display and back stainless
steel body with connecting terminal block. Both parts of the clock are held together by neodymium
magnets.
• Remove the front panel from the clock body. The panel is held by magnets, relatively high force
required to remove it.
• Disconnect the interconnecting cables by decoupling the terminals on the control PCB. Disconnect
the earth wire connecting the clock body to the front panel.
•
Drill appropriate number of anchoring holes into the wall of a diameter adequate to accommodate
appropriate screws of 4 to 5 mm diameter. Use dowels if necessary. As a template for marking
the position of the dowels, the clock body can be used.
•
Pull the incoming conductors through the hole in the clock body and fix the clock body to the wall.
•
On the mains powered clock loosen the screw on the underside of the 230 VAC terminal cover
and remove the cover. Unscrew the cable clamp.
• Connect the incoming conductors in accordance with the descriptive sheet placed next
to the connecting terminal block. Give the conductors an appropriate shape or cut them off to a length
that will not obstruct the placement of the front part of the clock into the clock body.
•
On mains powered clock mount the 230 VAC terminal cover back and secure it by tightening the screw
on the underside of the cover.
• Carefully shape all incoming cables into the clock and secure them by screwing the cable clamp.
•
Mount the connectors to the cable of the temperature sensor, to the keyboard cable, Ethernet
or to the RS 485 interface connectors if these are used.
•
Push the temperature sensor, the keyboard connector, Ethernet connector or the RS 485 jacks
into the corresponding terminals on the control PCB.
ď
Be careful not to swap the terminals. Check the markings of the jack‑plugs.
•
Connect the interconnecting cables into the corresponding terminals on the clock control PCB.
Reconnect the earth wire to connect the clock body to the front panel.
• Put the front panel into the clock body. Check the cables to prevent them from being pinched between
the back of the front panel and the clock body.
7.5.4.2
Single sided – ceiling suspension, wall bracket
• The single sided clock consists of two parts, one front panel and stainless steel clock body
with connecting terminal block. The front panel is held together by neodymium magnets. The clock
suspension part is delivered separately.
•
Pull the incoming conductors through the pipe which serves as the clock suspension. Fix the ceiling
suspension (or the wall bracket) to the ceiling (or the wall) using 4 appropriate screws of 5 mm
diameter. Use dowels if necessary.
• Remove the front panel from the clock body. The panel is held by magnets, relatively high force
required to remove it.
•
Disconnect the interconnecting cables by decoupling the terminals on the control PCB. Disconnect
the earth wire connecting the clock body to the front panel.
Содержание DSC. 250.4
Страница 1: ...BE 801372 01 Digital_clocks_manual 221114 MOBATIME Instruction manual Digital clocks ...
Страница 31: ...MENU 31 BE 801372 01 Digital_clocks_manual 221114 MOBATIME ...
Страница 141: ......
Страница 142: ......
Страница 143: ......