6 Faults
6.1 Correcting faults
This section describes the steps to be taken in the event that faults occur
on the unit during operation.
1.
Observe the instructions in
.
2.
Contact customer service.
6.2 Safety temperature limiter (STL) triggered
CAUTION
Damage of the safety temperature limiter due to improper switching
back on
→
Allow unit to cool down.
→
Determine the cause of the triggering and eliminate it.
The safety temperature limiter is a safety device that prevents the unit
from being damaged.
It is triggered when
●
the unit exceeds its maximum operating temperature
●
the ambient temperature falls below 0 °C
If the maximum operating temperature is exceeded, the unit's heating
switches off.
6.2.1
Switching the STL back on after exceeding the
maximum operating temperature
1.
Allow unit to cool down.
2.
Determine the cause of the STL triggering.
3.
Eliminate the cause.
4.
Remove the cap in the switch cover.
5.
Press the red unlocking button.
6.
Replace the cap in the switch cover.
Operating manual
26
Deep fat fryer (electric)
Faults