![MJK MagFlux Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/mjk/magflux/magflux_installation-and-user-manual_1812930031.webp)
31
Electromagnetic Flow Meter
FW: 841012/842009
Remote Flow Sensor
Connect the remote flow sensor to the flow converter with the included
cable (part number 691080).
Important
: Do not use other cable types!
The extension cable length between converter and sensor must under
normal circumstances not exceed 100 meters. Power lines running in par-
allel and noisy environments may reduce the max. length to 50 meters.
Consult MJK personnel for advice and guidance.
Remote Flow Sensor
Terminal
Signal
Designation
Colour
1
Liquid GND
Shield
-
2
E1
Wire pair no. 1
Red
3
E2
Wire pair no. 1
White
4
GND
Wire pair no. 3
Black
5
L1
Wire pair no. 2
Green
6
L2
Wire pair no. 2
White
7, 8 and 9
not used