![MJK MagFlux Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/mjk/magflux/magflux_installation-and-user-manual_1812930015.webp)
15
Electromagnetic Flow Meter
FW: 841012/842009
3. Flow Sensor
The following conditions must be satisfied to get the full benefit of the
MagFlux
®
flow sensor.
Minimum conductivity
The
•
conductivity of the media must be greater than 5 µS/cm.
Liner selection
Use
•
Teflon
®
lining
for chemicals and food industries
Use
•
hard rubber lining
for drinking water and waste water
Use
•
soft rubber lining
for water with abrasive particles
Electrode selection
Steel AISI 316TI-1.4571
•
for general purpose, sewage, water and district
heating systems
Hastelloy
•
for sea water
Titanium and platinum
•
for chlorine and other aggressive chemicals
Mounting location
To obtain a stable and accurate flow measurement, it is very important
•
that the flow sensor is mounted correctly in the pipe system
There must be no flow fluctuations
•
Avoid locations where vacuum can occur; especially for flow sensors
•
with Teflon™ linings
Avoid locations with vibrations from for example pumps
•
Avoid locations with extensive temperature changes
•
Avoid corrosive environments and locations with a great risk of con-
•
densation, or consult factory for special builds for these locations
Take care that condensate and water cannot enter the connector box
•
on the flow sensor.
There must be sufficient free space around the flow sensor.
•
Observe that the correct flow directions are set in the
•
MagFlux
®
"Con-
verter Setup" menu and in the "Service Menu" (default flow direction is
"A").
Содержание MagFlux
Страница 6: ...6 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Страница 12: ...12 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Страница 38: ...38 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Страница 106: ...106 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Страница 144: ...144 GB MagFlux Manual 0812 Electromagnetic Flow Meter This page intentionally left blank...
Страница 149: ...Index 5 GB MagFlux Manual 0812 Electromagnetic Flow Meter Electromagnetic Flow Meter This page intentionally left blank...