17
Installation: electrical
External controller wiring
Mixergy systems can be connected to an external controller using
the sense cable as follows:
• Connect the brown (L) cable to the external controller ‘DHW
ON’ junction.
• Connect the blue (N) cable to neutral.
• Connect the green and yellow (E) cable to ground.