Foreword

 

This  instrument  is  a  Linear  Gage  0.1

μm  Resolution.  To  obtain  the  highest  performance  and  the  longest 

service life from your Linear Gage, carefully read this manual thoroughly prior to setup and operation. After 
reading this manual keep it near the Linear Gage for quick reference. The specifications of this gage and the 
description in this manual are subject to change without prior notification. 

Safety Precautions 

To ensure operator safety, use the instrument in conformance with the directions and specifications given in 
this User

’s Manual.   

 If  a  contact  point  with  a  sharp  tip  is  used,  exercise  sufficient  care  in  handling  during 

replacement or use of it so as not to get hurt.

 

 If a contact point is released freely after it has been pressed in, the contact point may burst 

forth at a very high speed depending on the amount of spindle travel.    Sufficiently exercise 
care so that your fingers or hand may not be pinched.

 

Precautions for Use 

Carefully avoid the following attempts and conditions to protect the instrument from failure and malfunction.   

IMPORTANT 

 Do not apply sudden shocks including a drop or excessive force to the linear gage. 

 Do not disassemble or modify the gage.   

 Do not use and store the gage at sites where it is exposed to direct sunlight or at extremely hot or cold sites. 

 To use the gage highly accurately, avoid sites where the temperature will change abruptly. 

 Absolutely do not apply an electric engraver to the gage. The high voltage may damage electronic parts. 

Also, do not use the gage at sites where it is subject to large electric noises. 

 Do not exert load on the spindle in the perpendicular direction and do not twist the spindle. 

 Do not clamp the stem too tightly, since the spindle will not move smoothly. 

 Do not apply excessive tension to the cable or do not bend it forcibly. 

 To perform stable measurement, allow at least 10 minutes after turning on the power. 

 Do not set up the origin point at either end of the stroke. 

 If the gage is used in combination with other instruments, the maximum performance could not be obtained 

depending on environmental and operating conditions. Take those conditions into consideration prior to use.   

  The functions and performance will not be guaranteed, if the gage is used in other conditions than those s pecified.   

 Tale sufficient damage-preventive processing (safety measures), should this gage have been at fault.   

 A  contact  point  could  hurt  a  workpiece  depending  on  the  workpiece  material,  measuring  force,  impact 

when the contact point comes in contact with the workpiece, etc.    Check that there is no problem of hurts 
on  a  workpiece  during  measurement  or  accuracy  variation  depending  on  the  measuring  force,  etc.,  in 
advance of use. 

 

Electromagnetic Compatibility (EMC) 

This product complies with the EMC Directive. Note that in environments where electromagnetic interference 
exceeds  EMC  requirements  defined  in  this  directive,  appropriate  countermeasures  are  required  to  assure 
the product performance. 

 

Disposal  of  Old  Electrical  &  Electronic  Equipment  (Applicable  in  the  European 
Union and other European countries with separate collection systems)

 

This symbol on the product or on its packaging indicates that this product shall not be treated 
as  household  waste.  To  reduce  the  environmental  impact  of  WEEE  (Waste  Electrical  and 
Electronic  Equipment)  and  minimize  the  volume  of  WEEE  entering  landfills,  please  reuse 
and recycle. 
For further information, please contact your local dealer or distributors. 

 

Export Control Compliance 

The  goods,  technologies  or  software  described  herein  may  be  subject  to  National  or  International,  or 
Japanese  Export  Controls.  To  export  directly  or  indirectly  such  matter  without  due  approval  from  the 
appropriate authorities may therefore be a breach of export control regulations and the law. 

1. Name and Dimension of Each Part 

 
 

(1)Stem 
(2)Rubber boot 
(3)Spindle 
(4)Contact point 
(5)Output cable 
(6)Output connector   
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

2. Mounting the Gage 

To mount the gage on another instrument or a fixture, clamp the 

Φ8 stem or Φ15 stem.   

It is recommended to use a slotted holder or a split bushing for the mount structure. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

IMPORTANT 

 Absolutely avoid pressing the stem directly with set screws. 

    (The built-in bearing may be damaged.) 

 Notice that excessively tightening the stem can cause trouble in the spindle operation. 

 Never fix a linear gage at other than the stem. 

 Mount the gages so that the spindle is directed perpendicular to 

the measured surface. If the gage is mounted at an angle to the measured surface,   
an error may be generated in measurement results. 

 Exercise care so as not to exert a force on the gage through the cable. 

 

3. Precautions in Protecting the Gage from Dust and Water 

IMPORTANT

 

 The output connector plug and preamplifier (counter side) is not protective structured. Install the gage at a 

place where it is not splashed directly with water or oil.   

 If an extension cable is used, completely cover the preamplifier and connector area with a seal so as not to 

be exposed to environments. 

 If the cable covering is broken, liquid will penetrate into the gage inside due to capillary phenomenon. This 

will cause damage to the gage. Immediately repair the cable.   

 Be  greatly  careful  not  to  damage  the  rubber  boot  due  to  chips,  etc.  If  the  rubber  boot  is  damaged, 

dust-proof function will be deteriorated. Immediately replace or repair the rubber boot.   

 The materials including rubber which are used for the rubber boot and other sealing parts are not universal 

against  diversified  coolants  and  chemicals.  If  those  parts  deteriorate  unusually,  consult  the  nearest 
Mitutoyo Service Center. 

 If linear gages are used in adverse environments where they are subject to frequent splashes of water and 

oil, it is recommended to take preventive measures such as replacing them before being damaged. 

 Each part of the gage is sealed up, and therefore must not be disassembled. If any part is disassembled, 

the rated performance will not be obtained. Do not absolutely disassemble the gage. 

 

4. Connecting the Gage to a Counter 

Connect  the  output  connector  of  the  gage  to  the  input  connector  on  a  linear  gage  counter.  For  detailed 
information, refer to the user

’s manual of the linear gage counter.

 

IMPORTANT 

 If the gage cable is close to the power line for other instruments, the gage may malfunction. Connect the 

gage cable as apart from the power line as possible. 

 If the gage is connected with other counter than Mitutoyo made, allow at least 0.2 second after the gage is 

turned on, then reset the counter. 

 

5. Gage Output Signals 

1) Output connector: RM12BPE-6PH (Hirose) 
2) Pin assignment 

Pin No. 

Signal name 

Pin No. 

Signal name 

Pin No. 

Signal name 

+5V *3 

ΦB 

GND 

ΦA 

ΦA 

ΦB 

*3: Power supply to the gage head 

Power voltage; 5V (4.8N to 5.2V), 
Ripple voltage: 200mVp-p or less   
Current consumption: 120mA max. 

3) Input/output signal level 

ΦA, ΦA, ΦB, ΦB, ΦZ (TTL line driver AM26LS31 or equivalent) 

4) Output signal chart 

This  series  of  gages  are  provided  with  the  following  three  patterns  for  their  output  signals.  Therefore, 
always design the reception circuitry so that it includes an error detecting process making use of these 
patterns: 
(A) Real-time pulse output (Phase-A wave advances when the spindle is retracted.)

 

 
 
 
 
 
 
 

(1) Output condition: Spindle moving speed 

≤ Gage response speed *4 

(2) Minimum edge-to-edge interval of output pulses: Tr = 0.2 

μs 

(3) Output delay time *

5

: Max. 2.5 μs 

Linear Gage   

LGF-0110L-B / 0125L-B 

 

LGF-0125L-B 

ΦA 

ΦB 

Tr (minimum) = 

0.2μs 

⇒ 

0.1 μm (resolution) 

  *1: For 10mm Stroke type 

  *2: For 25/50mm Stroke type

 

Cross section 

Split bushing 

Cross section 

*2

 

*1

 

(90

°

with respect to tap)

 

+0.020
+0.005 

Unit:mm

 

Example2 

Example1 

1

 

*2

 

15

 

7.5

 

6

 

16

 

15

 

7.5

 

M4x0.7thru 

4.5 drill, 7.5 countersink, 4.4deep 

20

 

15

 

7.5

 

M4x0.7thru 

10

 

15

 

6

 

Φ

8

 

Φ

15

 

*2

 

*1

 

Φ

10

 

Φ

17

 

(1)

 

(1)

 

Notch position

 

(2)

 

(2)

 

15

 

 

Φ

15

 

Φ

8

 

*1

 

*2

 

Φ

17

 

Φ

10

 

*1

 

+0.024
+0.006 

+0.020
+0.005 

 

+0.024
+0.006 

-0.

015

 

-

0.

018

 

+0.

020

 

+0

.005

 

+0.

024

 

+

0.

006

 

NOTE 

 

 

2

 

3

 

4

 

6

 

5

 

1

 

(Hirose) 

(Thread height) 

Cable length = 2m 

(Thrust stem mounting screw) 

1

0

.6

 o

m

o

re

 

(st

ro

ke

(Thread height) 

(Hirose) 

Cable length = 2m 

Thrust stem   

mounting screw 

26

 o

m

o

re

 

(st

ro

ke

θ

 

Error = L0 - L1 

LGF-0110L-B 

No. 99MBC104B1 

Series No. 542 

 

Отзывы: