1.  Names of Components

CGF-X

 Clamp screw

 Indicator holder

 Grip

 Pipe (outer sleeve)

 Measuring head

 Supporting nut

 Anvil

 Adjustment washer

 Guide

 Contact point (contact rod)

 Guide stopper screw

 Contact rod holder

Tips

No guide (guide plate) is provided with CG-S10A.

2.  Preparation for Measurement

1) Setup

NOTICE

• Confirm that the measuring head or screw is not loosened before use.

• Do not insert, remove, or turn the indicator with the clamp screw tightened, as it will lead to 

breakage.

• If the insertion hole of the indicator holder is accidentally deformed, correct it by inserting a

ø8 mm rod for the metric type and a ø9.53 mm rod for the inch type.

• Secure fixation may be impossible when the indicator or the indicator holder insertion hole or 

the clamp screw is dirty. Clean them in advance.

1

3

Dial protection cover

Clamp screw

1

   Loosen the clamp screw and insert the indicator into the indicator holder.

2

   Tighten the clamp screw to fix the indicator.

Tips

Firm tightening is possible by turning with an object such as a coin inserted in the groove on the 
clamp screw head.

3

   When required, attach a dial protection cover (optional depending on models).

4

   For models with a measurement range of 160 mm or more, the direction of the guide unit must 

be switched.

1. Push the guide until it hits the end lightly.
2. Turn 90 degrees clockwise.
3. Let go.

 The guide returns to the reference point position, and the product is ready for measurement.

1

2

Safety Precautions

To ensure operator safety, use this product in conformance with the directions, functions 

and specifications given in this User’s Manual.
Use under other conditions may compromise safety.

NOTICE

•  Do not disassemble or modify. This may cause damage.
•  Do not use or store the product in a place with sudden temperature changes. Adapt the 

product to room temperature before use.

•  Do not store the product in a place with high humidity or a lot of dust.

•  Do not apply impact or excessive force to this product.

•  Be sure to perform reference point setting before measurement.
•  Remove dust, cutting chips, etc. before and after use.
•  After use, clean and perform anti-rust treatment for the body, anvils, adjustment washers, 

etc. Insufficient cleaning may cause accuracy or operation to suffer.

•  For periodic calibration or precision measurement, wear thick gloves in order to reduce 

changes in the indicated value caused by the transmission of body temperature.

•  Indicators with rubber bellows such as waterproof dial gages cannot be used.

Tips

The bore gage is a comparator. It will not function as a measuring instrument if used alone. 
An indicator such as a dial gage and a reference gage such as a set ring or micrometer are 
required to use the product.

Bore Gage

User's Manual

No.99MAJ005A

CG-SA

CG-AX

CGB-X

CGF-X

CGM-X

Model/Code No. List

Model

Code No.

CG-S10A

511-209

CG-S18A

511-201

CG-S.4"A

511-214

CG-S.7"A

511-205

CGB-35X

511-761

CGB-60X

511-762

CGB-150X

511-763

CGB-160X

511-764

CGB-1.4"X

511-781

CGB-2.5"X

511-782

Model

Code No.

CGB-6"X

511-783

CGB-6.5"X

511-784

CG-35AX

511-701

CG-60AX

511-702

CG-150AX

511-703

CG-160AX

511-704

CG-250AX

511-705

CG-400AX

511-706

CG-1.4"AX

511-731

CG-2.5"AX

511-732

Model

Code No.

CG-6"AX

511-733

CG-6.5"AX

511-734

CG-10"AX

511-735

CG-16"AX

511-736

CGF-35X

511-415

CGF-60X

511-416

CGF-150X

511-417

CGF-1.4"X

511-418

CGF-2.4"X

511-419

CGF-6"X

511-420

Model

Code No.

CGM-100X

511-803

CGM-160X

511-804

CGM-250X

511-805

CGM-400X

511-806

CGM-600X

511-807

CGM-800X

511-808

CGM-4"X

511-833

CGM-6.4"X

511-834

CGM-10"X

511-835

CGM-16"X

511-836

Model

Code No.

CGM-24"X

511-837

CGM-32"X

511-838