Содержание 542-715

Страница 1: ...Catalog No 13013 3...

Страница 2: ...000 No 971753 14 000 PC SENSORPAK No 02NGB070 80 000 mm LGH No 971750 LGH 23kg No 971753 50g LGH PC SENSORPAK No 02NGB070 15H7 25 350 100 250 50 34 175 300 110 80 270 LGH 1010 C B EH 0 137mm LGH 0510...

Страница 3: ...40C 20C 20 80 RH 15 25 20 30 60 RH 10C 60C 20 80 RH 10 60 20 80 2 999 99999mm 99 999995mm 3 5 RS RINK RS 232C USB SENSORPAK DP 1VR 3 I O RS 232C 3 I O BCD 4 4 AC DC 12 24V MAX700mA 8 4W MAX 700mA 1 1A...

Страница 4: ...2 1161 1 4 34 559 0034 06 6613 8801 06 6613 8817 078 924 4560 2 13 27 3 1F 525 0032 077 569 4171 077 569 4172 134 107 700 0951 086 242 5625 086 242 5653 2 15 20 739 0142 082 427 1161 082 427 1163 4 16...

Страница 5: ...1010 B EH LGH 1010C B EH No 99MBC122A4 Date of publication December 1 2020 1 User s Manual Instructions for use Read this document thoroughly before operating the product After reading retain it clos...

Страница 6: ...nts y y Particularly for full understanding of information carefully read Safety Precautions and Precau tions for Use at the outset of this document before using the product y y The contents in this d...

Страница 7: ...ich if not avoided may result in minor injury NOTICE Indicates a potentially hazardous situation which if not avoided may result in property damage Alerts the user to a specific hazardous situation th...

Страница 8: ...the spindle rubber cap or cable Installation environment This product is designed for indoor use To ensure optimal performance for this precision equipment take the following conditions into account w...

Страница 9: ...connect the AC adapter to high current power used by machine tools or large CNC mea suring instrument If you use a commercial power source use a power cable measuring 30 m or shorter for the instru me...

Страница 10: ...he technology including Programs you shall observe the regulations of your country Please contact Mitutoyo in advance Notes on Export to EU Member Countries When you intend exporting of this product t...

Страница 11: ...No 99MBC122A v China RoHS Compliance Information This product meets China RoHS requirements See the table below Pb Hg Cd Cr VI PBB PBDE SJ T 11364 GB T 26572 GB T 26572 SJ T11364 2014...

Страница 12: ...mage owing to fire salt gas abnormal voltage lightning surge or natural disaster y y Failure or damage owing to use in combination with hardware or software other than those desig nated or permitted b...

Страница 13: ...toyo is found to be liable to you for any damage or loss which arises out of or is in any way connected with use of this product by you in no event shall Mitutoyo s and or its affiliated and related c...

Страница 14: ...z z Other DP 1VA LOGGER Digimatic Mini Processor User s Manual Intended readers and purpose of this document z z Intended readers This document is intended for beginners of LGH series Linear Gages The...

Страница 15: ...z When you do not know the appropriate operation while using this product Look for the page with the desired operation in the table of contents z z Terms and definitions y y Internal counter CEL Four...

Страница 16: ...Countries with Separate Collection Systems iv China RoHS Compliance Information v Warranty vi Disclaimer vii About This Document viii Contents x 1 Overview 1 1 1 Main Configurations 1 1 2 Part Names...

Страница 17: ...Setting 33 4 5 1 Procedure for Switching Peak Mode 33 4 5 2 Procedure for Clearing Peak Value 33 4 6 Tolerance Value Setting 34 4 6 1 3 Step Tolerance Value Setting 3 Step Tolerance Zone Selection 34...

Страница 18: ...on 50 5 5 3 Input Function 51 5 5 4 Timing Chart 52 6 Troubleshooting 55 6 1 Troubleshooting 55 6 2 Error Messages 56 6 2 1 List of Error Codes 56 6 2 2 Error Cancellation Method 58 7 Specifications 5...

Страница 19: ...re to use it in combination with the supplied EH Counter dedicated to LGH Measurement stand Holder A Holder B Dedicated release etc Code No 542 715 LGH 1010 B EH Minimum resolution 0 01 m Code No 542...

Страница 20: ...M2 5 Cable length Approx 2 m No Name Notes Stem Spindle rubber cap LGH 1010C B EH does not have a rubber cap Contact point Part No 901312 Release mount screw Connection cable connector Signal connect...

Страница 21: ...judgment by color UNIT indicator y y Blinks while a HOLD signal is being input when the I O con nector is connected y y Lights when an E unit has been selected for the correspond ing parameter SEL ke...

Страница 22: ...ing an I O connecting cable DC jack For connecting the AC adapter Power switch For turning the power on and off Grounding terminal For connecting a grounding wire Cable clamp For securing the power ca...

Страница 23: ...the master workpiece as necessary Tips Perform adequate thermal stabilization of this product and the workpiece Turn on the power warm up the product for 30 minutes or more and start measurement Set...

Страница 24: ...t before mea suring This product does not guarantee accuracy in a range of 0 2 mm from the bottom dead center spindle in the state protruded most Lift the spindle 0 2 mm or higher from the bottom dead...

Страница 25: ...4 Stand for EH Counter 1 Washer for EH Counter 6 AC adapter 1 357651 AC adapter power cable for use in Japan and other countries 1 02ZAA000 DC plug MP 121M 1 214938 Inspection report 1 User s Manual t...

Страница 26: ...e external dimensions and measuring force and the measuring direction may be limited Depending on the shape use of a contact point other than those supplied may cause errors to accumulate 1 Remove the...

Страница 27: ...a fixation part of the gage head 3 Tighten the fixation screw to secure the gage Process the gage mounting hole to be parallel to the measurement direction A tilted gage will result in a measurement...

Страница 28: ...lease optional see 7 3 Option page 62 2 2 2 Counter Procedure for mounting to a panel 1 Cut a rectangular opening in the panel for mounting the counter Width mm Height mm Panel thickness mm 138 5 139...

Страница 29: ...on a desk attach the supplied four rubber feet as shown in the figure below Rubber foot Tips This product cannot be mounted in a panel with the rubber feet attached To use the counter tilted approx 10...

Страница 30: ...ial power source use a power cable measuring 30 m or shorter Avoid outdoor wiring Never use this power source with other electric equipment that runs at a high voltage and or large current 2 3 2 Conne...

Страница 31: ...signal connection cable through a cable duct together with other power lines Tips Secure the power cable and connecting cables for external equipment to your equipment with a cable tie cable holder e...

Страница 32: ...lue status Tips Pressing A_ZERO performs Zero setting for each axis and then the counter enters the counter value status 3 Check that the counter value is shown on the Display 4 Make sure that the cou...

Страница 33: ...he retainer misalignment after power on and before thermal stabilization 1 Turn on the power switch on the back of the counter The counter enters the stand by state 2 With the contact point free press...

Страница 34: ...16 2 Setup No 99MBC122A MEMO...

Страница 35: ...arameters 1 Turn on the power switch The counter enters the stand by state 2 Press and hold P SET and then press A_ZERO The counter enters Parameter mode 3 Press P SET repeatedly to display the parame...

Страница 36: ...e this setting has been enabled this parameter is initialized to reset the set value to 0 disable 0 Disabled one shot 1 Clear reset to the initial values 02 Key protect Disables key operations to prev...

Страница 37: ...e 3 Not available 11 Selection of counter direction You can set whether the numeral will increase or decrease when the spindle is pushed in per axis Since this product does not allow input for the B a...

Страница 38: ...ositive logic 0 or negative logic 1 for BCD output For 000000 output the values in and indicate the voltages of the DATA line and the sign respectively 0 DATA L sign H 1 DATA H sign L 24 RS 232C USB D...

Страница 39: ...0 19990 2 199900 199900 1 Modifying this parameter clears the preset and tolerance values 2 Turn off the power switch after changing the setting The setting will be applied when you turn on the power...

Страница 40: ...B axis Not available Not available Not available Input circuit unit UNIT_A UNIT_F are provided for functions y y UNIT_A Performs a counter measurement for A axis y y UNIT_D Performs a simple speed me...

Страница 41: ...ircuit units UNIT_B UNIT_C or UNIT_E cannot be used for this product For details about the parameter setting see 3 1 Procedure for Setting Parameters page 17 For details about the CEL specific paramet...

Страница 42: ...UNIT_B B axis counter Default value UNIT_C A B Default value UNIT_A A axis counter Default value Tips The set values 0 4 of Parameter Number 06 do not allow the connection from UNIT to CEL to be modif...

Страница 43: ...saved in Bch lower display In addition to the most recently saved data the maximum and minimum values from past data can also be read out The saved data are not cleared even if the power switch is tu...

Страница 44: ...n the sampling cycle The maximum speed in the reverse direction is displayed when the minimum value MIN is selected in Peak mode The speed display is simplified and may not be correct z z Optional one...

Страница 45: ...with a constant Sets whether or not to multiply the internal counter value by one of the prede termined values or an arbitrary value The internal counter value multiplied by the specified constant val...

Страница 46: ...the number advances to the last number it then returns to 00 If you select a set value 1 CEL specific parameter setting for Parameter Number 00 you go to Parameter Number 40 When the number advances t...

Страница 47: ...41 Calculation with a constant 42 Hide the lowest order digit 20 Tolerance BCD output switchover 21 BCD output logic 24 RS 232C USB Digimatic output switchover 25 Data transfer speed 26 Parity check 2...

Страница 48: ...30 3 Parameter Setting No 99MBC122A MEMO...

Страница 49: ...e operation axis is the one used for RS 232 communication For details see 5 4 RS LINK Function page 46 When the calculation with a constant is set is displayed in the LED of the least significant digi...

Страница 50: ...he I O connector can also be used for preset When the I O connector input output is used the Preset value set in advance is used for preset 1 Press SEL to select one of the operation channels from Ach...

Страница 51: ...current value measurement and the peak measurement MAX MIN and TIR For details see 7 1 Basic Specifications page 59 4 5 1 Procedure for Switching Peak Mode 1 Press SEL to select one of the operation c...

Страница 52: ...S1 Measured value S4 Green indicator on AL3 BL3 S4 Measured value Red indicator on AL5 BL5 This section explains how to set the 3 step tolerance value 1 Press SEL to select one of the operation chann...

Страница 53: ...L4 S4 Measured value Red indicator on AL5 BL5 This section explains how to set the 5 step tolerance value 1 Press SEL to select one of the operation channels from Ach upper display and Bch lower displ...

Страница 54: ...K NG indicator changes to the one of the next tolerance value to be set 7 Set the tolerance values S2 S3 and S4 with the similar operations in the steps 3 5 8 Press LIMIT The tolerance value S4 is det...

Страница 55: ...number to be modified 4 Press A_ZERO to modify the set value of the parameter 5 Press and hold P SET and then press A_ZERO The counter returns to the counter value status 4 7 2 Procedure for Setting D...

Страница 56: ...MODE The input digit will shift to the right 5 Press A_ZERO The value changes available range 9 99999 Display A Display B 6 Press and hold P SET and then press A_ZERO The CEL number changes Display A...

Страница 57: ...of Ach upper display is saved in Bch lower display z z Procedure for reading saved data 1 Press SEL to select Bch lower display 2 Press MODE switch to Peak setting mode Each time you press MODE the d...

Страница 58: ...40 4 Basic Operations No 99MBC122A MEMO...

Страница 59: ...Digimatic Mini Processor DP 1VA LOG GER which is sold separately To do this connect the Digimatic cable to the RS_LINK connector OUT of the counter Tips A maximum of 6 digits can be printed When the...

Страница 60: ...mmercial RS 232C cross type cable 2 RXD IN 3 TXD OUT 4 DTR OUT 5 GND 6 DSR IN 7 RTS OUT 8 CTS IN 1 9 NC 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Pin number Pin number Counter side PC side Pin number Signal...

Страница 61: ...01 to 99 00 means all channels Channels 01 to 04 correspond to CEL1 to CEL4 respectively A after G in the output data denotes the type of data N Current value X Maximum value M Minimum value W TIR 2 I...

Страница 62: ...d from the keyboard to the counter using the Hyperterminal software installed with Windows by default 5 3 3 Saving and Loading Parameters You can output the set parameter data from the counter to a PC...

Страница 63: ...explains how to load parameters Tips When loading parameters you cannot extract only one parameter to change it Be sure to describe all parameters in one file and load them If parameters are set inco...

Страница 64: ...wn in the following figure IN OUT RS LINK IN OUT IN OUT RS 232C RS LINK RS LINK First counter Last counter Max 10 counters Max 10 m RS LINK connection cable Tips Do not connect anything to the RS_LINK...

Страница 65: ...BANK2 ChA ChB CH05 CEL1 CEL2 BANK1 CEL3 CEL4 ChA ChB BANK2 ChA ChB CH06 CH07 CEL1 CEL2 BANK1 CEL3 CEL4 ChA ChB BANK2 ChA ChB CH08 CH09 CH10 CH11 RS 232C First counter P No 06 5 Optional one axis setti...

Страница 66: ...nternally connected to GND COM Internally connected to GND 3 O AL1 Ach upper display tolerance judg ment result output y y Relevant terminal output L y y Output on error AL1 AL5 L A_bit0 Ach upper dis...

Страница 67: ...oint will blink 36 I PB Bch lower display Preset Peak clear in Peak HOLD mode During input the decimal point will blink Tips For external input negative logic L enabled is used I O refers to the first...

Страница 68: ...green under normal conditions and in red when an error has occurred For details on the timing chart see 5 5 4 Timing Chart page 52 BCD output Outputs measurement data in BCD format Measurement data fr...

Страница 69: ...n numbers 22 24 Bch lower display Pin numbers 23 24 1 0 V 4 0 V 2 5 V 0 1999 1999 Output voltage 2 5 V counter value voltage resolution 0 75 mV full scale 1 0 V 4 0 V Response speed 10 Hz update time...

Страница 70: ...DCK READY Max 5 ms Min 10 ms x 8 80 ms Min 2 ms Min 5 ms Min 5 ms Min 5 ms Tips SET1 and BCDCK BCD clock denote input signals and READY denotes the output signal The BCD data D1 D2 in the figure above...

Страница 71: ...the displayed BANK PA PB pin numbers 35 36 Preset Peak clear SET3 SET2 SET1 BANK1 H H H BANK2 H H L SET3 SET2 SET1 Preset H H H Peak clear H H L MODE pin number 29 Switching Peak A B_HOLD pin numbers...

Страница 72: ...RMAL is H error state Cancel the error state before use Data HOLD Min 10 ms Max 15 ms Min 10 ms 10 s HOLD Data output Data latch Tips During the peak detection the peak value will be cleared when PA P...

Страница 73: ...mber 41 to 0 The gage output signal pitch is changed Set Parameter Number 10 to an appropriate value For details see 3 2 List of Parameters page 18 Cannot execute Zero setting Peak mode is active Canc...

Страница 74: ...uption has occurred y y SEL y y CS00CRLF RS y y HOLD input I O Error 20 Red indicator on Error_20 H L1 L L5 L FFFF20 Overspeed Revise the measurement condi tions y y SEL y y CS00CRLF RS y y HOLD input...

Страница 75: ...r setting error y y Input the tolerance value again y y Input the parameter value again SEL Error 95 Normal output L Counter value status Counter value status Key protect Cancel the key protection par...

Страница 76: ...he 3 main error cancellation methods are explained below but the appropriate method differs de pending on the cause y y Automatic cancellation y y Press SEL y y Input an external HOLD signal Tips For...

Страница 77: ...upwards 0 45 N or less Not available Available counter EH Counter dedicated to LGH 1010 B Standard accessories Power supply Power con sumption 2 Supplied AC adapter or DC 12 V 24 V Max 8 4 W Max 700...

Страница 78: ...7 Specifications No 99MBC122A 7 2 Outline Dimensional Drawing 7 2 1 Gage Head Signal Connection Cable R20 Stroke Carbide S 3 contact point M2 5 Cable length Approx 2 m Minimum cable bending size Unit...

Страница 79: ...61 7 Specifications No 99MBC122A 7 2 2 Counter Unit mm using the rubber feet using the stand tilt angle when using the stand Approx 10 using the stand Fixation of power cable...

Страница 80: ...n cable 0 5 m 936937 RS LINK Digimatic connection cable 1 m 965014 RS LINK Digimatic connection cable 2 m 02NGB070 SENSORPAK software for loading data to PC 21HZA137 I O CABLE SET FOR SENSORPAK RS 232...

Страница 81: ...pecifications No 99MBC122A Holder A Unit mm Drill through Countersinking depth 5 5 M4 Hexagon socket head cap screw For fixing the gage Mounting reference surface Gage mounting hole Holder mounting su...

Страница 82: ...A Holder B Unit mm M4 Hexagon socket head cap screw For fixing the gage Mounting reference surface Gage mounting hole 2 M5 Effective depth 10 Holder mounting surface Release for LGH Total length 504 m...

Страница 83: ...65 No 99MBC122A...

Страница 84: ...29 U K Mitutoyo UK Ltd Joule Road West Point Business Park Andover Hampshire SP10 3UX UNITED KINGDOM TEL 44 0 1264 353 123 FAX 44 0 1264 354883 M Solution Center Coventry Unit6 Banner Park Wickmans D...

Страница 85: ...lings s SWEDEN TEL 46 0 8 594 109 50 FAX 46 0 322 63 31 62 M Solution Center V rnamo Storgatsbacken 1 331 30 V rnamo SWEDEN TEL 46 0 8 594 109 50 FAX 46 0 370 463 34 Switzerland Mitutoyo Schweiz AG St...

Страница 86: ...in Amphur Sriracha Chonburi 20230 THAILAND TEL 66 2080 3563 FAX 66 3834 5788 ACC Branch M Solution Center 122 8 122 9 Moo 6 Tambon Donhuaroh Amphur Muangchonburi Chonburi 20000 THAILAND TEL 66 2080 35...

Страница 87: ...ong Daegu Business Center 301 Ho 217 Seongseogongdan ro Dalseo gu Daegu 42704 KOREA TEL 82 53 593 5602 FAX 82 53 593 5603 China Mitutoyo Measuring Instruments Shanghai Co Ltd 8th Floor Tower 1 Lujiazu...

Страница 88: ...978 3501 M Solution Center Illinois 965 Corporate Blvd Aurora IL 60502 U S A M Solution Center Ohio 6220 Hi Tek Ct Mason OH 45040 U S A TEL 1 888 648 8869 FAX 1 513 754 0718 M Solution Center Michiga...

Страница 89: ...52 01 55 5312 3380 Monterrey Office M Solution Center Blv Interamericana No 103 Parque Industrial FINSA C P 66636 Apodaca N L M XICO TEL 52 01 81 8398 8227 8228 8242 8244 FAX 52 01 81 8398 8226 Tijua...

Страница 90: ...No 99MBC122A...

Страница 91: ...ecord Date of publication Revision status Details of revision February 1 2019 Revised Third edition Completely revised December 1 2020 Revised Fourth edition Revision due to changes of the harmo nized...

Страница 92: ...me Takatsu ku Kawasaki shi Kanagawa 213 8533 Japan Tel 81 0 44 813 8230 Fax 81 0 44 813 8231 Home page http www mitutoyo co jp global html For the EU Directive Authorized representative and importer i...

Отзывы: