11
-
4.3 Power blackout auto restart function
(1)
Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it
being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
(2)
The following settings will be cancelled:
(a)
Timer settings
(b)
High-power operations
Notes (1) The power blackout auto restart function is set at on when the air-conditioner is shipped from the
factory. Consult with your dealer if this function needs to be switched off.
(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
(3) If the jumper wire (J7) “AUTO RESTART” is cut, auto restart is disabled. (See the diagram at right)
Jumper wire (J7)
4.4 Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong operation
due to mixed signals, please modify the printed circuit board in the indoor unit’s control box
and the remote control using the following procedure. Be sure to modify both boards. If only
one board is modified, receiving (and operation) cannot be done.
(1)
Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (J6)
using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the lead
wires, etc.
(2)
Modifying the wireless remote control
(a) Remove the battery.
(b) Cut the jumper wire shown in the figure at right.
Jumper wire (J6)
Cut
Содержание SRK10CFV-4; SRK13CFV-4
Страница 2: ...TECHNICAL MANUAL...
Страница 34: ...PARTS LIST INDOOR UNIT SRK10CFV 4 SRK13CFV 4 OUTDOOR UNIT SRC10CFV 4 SRC13CFV 4...
Страница 37: ...CRAE0176 20 17 18 21 23 22 24 25 14 15 16 9 10 11 12 13 1 8 5 7 6 4 2 3 19 HEAT EXCH CONTROL 35...
Страница 41: ...CRAE0177 24 21 22 25 27 26 28 29 18 19 20 13 14 15 16 17 1 12 9 11 10 4 6 5 7 8 2 3 23 HEAT EXCH CONTROL 39...
Страница 43: ...CRBE0233 1 7 2 16 3 7 4 5 6 15 8 14 12 10 13 11 18 17 17 17 9 PANEL FAN ASSY 41...
Страница 45: ...CRBE0234 1 2 3 21 4 5 6 8 7 19 13 22 20 18 9 10 11 14 15 16 17 23 12 GAS LIQ HEAT EXCH CONTROL 43...
Страница 47: ...CRBE0239 1 7 2 16 3 7 4 5 6 15 8 14 12 10 13 11 17 17 17 9 PANEL FAN ASSY 45...
Страница 49: ...CRBE0235 23 1 2 3 4 22 5 6 7 9 8 20 14 21 19 10 11 12 15 16 17 18 13 GAS LIQ 24 HEAT EXCH CONTROL 47...
Страница 51: ...ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST Manual No 06 SRK T 056...