5.2 Serial Communication and Modem Interface Instruction
5.2.14 UINI instruction
5-77
5
QCP
U
IN
S
T
RUCTI
O
N
DE
TA
IL
S
Z_
UI
N
I
Z_UINI
5.2.14
UINI instruction
Z_UINI
*1: Local devices and file registers per program cannot be used as setting data.
Function
This instruction switches the mode, transmission specification, and host station number of the Q
series C24.
Z_UINI
Executing condition :
indicates the following instruction.
Z_UINI
Input argument
EN:
Executing condition
:Bit
Un*:
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
:String
s:
Variable that stores control data
:Array of ANY16 [0..12]
Output argument
ENO:
Execution result
:Bit
d:
Variable that turns ON upon completion of the instruction
d[1] also turns ON at the time of error completion.
:Array of bit [0..1]
Setting
data
*1
Internal device
R, ZR
J
\
U
\G
Zn
Constant Others
Bit
Word
Bit
Word
−
−
−
−
Structured ladder
ST
Z_UINI
EN
ENO
d
U
n
*
s
Z_UINI
(EN, U
n
*, s, d);
ENO:=
S
dd