2. PERFORMANCE SPECIFICATIONS

The following are the performance specifications of the Q68TD-G-H01.

(1) Performance specification list

Table 2.1 List of performance specifications

Item

Specifications

Number of channels

8 channels

Output

Temperature 
conversion value

16-bit signed binary (-2700 to 18200)

Scaling value

16-bit signed binary

Standard with which 
thermocouple conforms

JIS C1602-1995,IEC 60584-1(1995),IEC60584-2(1982)

Usable thermocouples and 
conversion accuracies *1

Refer to (2)

Cold junction temperature 
compensation accuracy *1

1.0

Accuracy *1

Depends on the formula listed in *2

Resolution

B,R,S,N : 0.3

  K,E,J,T : 0.1

Conversion speed *3

320ms/8 channels

Sampling period *4

320ms/8 channels

Number of analog input points

8 ch cold junction temperature compensation channel/module 

Isolation specifications

Disconnection detection

Not available *5

Maximum number of writes for 
Flash memory

50,000

Number of I/O points occupied

16 points (I/O assignment:Intelligent 16 points)

External wiring connection 
system

40-pin connector

Applicable wire size

0.3mm

2

 (AWG#22) or less

External device connection 
connector (option)

A6CON4

Internal current consumption
(5 VDC)

0.49A

Weight

0.18kg

External dimensions

98(H)

27.4(W)

90(D)mm

Specific isolated area

Isolation 

method

Dielectric 
withstand 

voltage

Isolation 

resistance

Between thermocouple 
input and programmable 
controller power supply

Transformer 

isolation

500VACrms 

for 1min.

500VDC 

10M

 

or more

Between thermocouple 
input channels

Transformer

isolation

1000VACrms

for 1min.

Between cold junction 
temperature compensation 
channel and programmable 
controller power supply

No insulation

-

-

Содержание Q68TD-G-H01

Страница 1: ...ogrammable controller MELSEC Q series 2007 MITSUBISHI ELECTRIC CORPORATION Channel Isolated Thermocouple Input Module Prior to use please read this and relevant manuals thorougly to fully understand t...

Страница 2: ...he precautions of both levels because they are important to personal safety Please keep this manual accessible when required and always forward it to the end user DESIGN PRECAUTIONS DANGER Do not writ...

Страница 3: ...ottom of the module fully insert the module fixing projection into the fixing hole in the base unit to mount the module Incorrect module mounting may cause a malfunction failure or drop of the module...

Страница 4: ...connected to the module in a duct or clamp them If not dangling cables may swing or inadvertently be pulled resulting in damage to the module and or cables or malfunctions due to poor cable connectio...

Страница 5: ...389 B Partly modified EMC and Low Voltage Directives Section 1 1 Chapter 2 Section 3 1 5 1 5 2 5 3 This manual confers no industrial property rights or any rights of any other kind nor does it confer...

Страница 6: ...PERFORMANCE SPECIFICATIONS 3 3 IMPLEMENTATION AND INSTALLATION 6 3 1 Handling Precautions 6 3 2 Installation Environment 6 4 PART NAMES 7 5 WIRING 9 5 1 Wiring Precautions 9 5 2 External Wiring 10 5...

Страница 7: ...ives compliant into other machinery or equipment refer to Chapter 9 EMC AND LOW VOLTAGE DIRECTIVES of the QCPU User s Manual Hardware Design Maintenance and Inspection The CE mark indicating complianc...

Страница 8: ...g describes the restrictions of the slot position when mounting the Q68TD G H01 with a combination of the power supply module and the base unit For the slot that the Q68TD G H01 cannot be mounted leav...

Страница 9: ...c Figure 1 3 Mountable slot position of Q68TD G H01 OUT I 01 I 01 CPU Slot No 0 Not mountable Mountable Power supply Slot No 1 Slot No 2 OUT I 01 I 01 IN Slot No 0 Not mountable Mountable Power suppl...

Страница 10: ...t points 8 channels cold junction temperature compensation channel module Isolation specifications Disconnection detection Not available 5 Maximum number of writes for Flash memory 50 000 Number of I...

Страница 11: ...accuracy is as follows 2 5 0 4 35 30 1 5 5 3 The conversion speed indicates the maximum time period from which the input temperature starts changing to which the temperature mesurement value of the bu...

Страница 12: ...9 5 1600 to 1760 3 3 3 K 270 to 200 3 3 3 200 to 0 2 Larger value of 0 5 and 0 5 of measured temperature Larger value of 0 06 and 0 2 of measured temperature 11 0 0 to 1200 2 Larger value of 0 25 and...

Страница 13: ...easily fixed onto the base unit using the hook at the top of the module When using the programmable controller in an environment of frequent vibrations however fix the module with a module fixing scr...

Страница 14: ...g timer error occurred or online module change enabled 2 ERR LED Displays the error status of the Q68TD G H01 On Error Flashing Error in switch settings Switch No 5 of the intelligent function module...

Страница 15: ...CH2 A4 B4 A5 CH3 B5 CH3 A6 B6 A7 CH4 B7 CH4 A8 B8 A9 CH5 B9 CH5 A10 B10 A11 CH6 B11 CH6 A12 B12 A13 CH7 B13 CH7 A14 B14 A15 CH8 B15 CH8 A16 B16 A17 B17 A18 B18 A19 B19 RTD A20 RTDG B20 RTD Seen from t...

Страница 16: ...igh frequency waves such as an inverter s load circuit Not doing so will cause the module more susceptible to noises surges and inductions 3 The following wiring is required for the product to comply...

Страница 17: ...the accuracy Moreover the Q68TD G H01 needs to be powered for 30 minutes warm up when the offset gain setting is performed and after the online module replacement is performed G CH1 CH8 G RTD A1 B1 A1...

Страница 18: ...ing a value other than 0 to 7 a thermocouple type settings error 10 indicates target channel number occurs and a temperature conversion is not performed Switch 2 Thermocouple type settings CH5 to CH8...

Страница 19: ...12 6 EXTERNAL DIMENSIONS Unit mm in 27 4 1 08 98 137 5 39 90 3 54 47 1 85...

Страница 20: ...e Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi E...

Отзывы: