22 -
33
22. TROUBLE SHOOTING
4010
[MISSING END INS.]
There is no END (FEND) instruction in the
program.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• At power ON/At reset/STOP
RUN
Read the common information of the error using a
peripheral device, check error step corresponding
to its numerical value (program error location), and
correct the problem.
RUN:
Off
ERR.:
Flicker
CPU Status:
Stop
QnA
4020
[CAN'T SET(P)]
The total number of internal file pointers used by
the program exceeds the number of internal file
pointers set in the parameters.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• At power ON/At reset/STOP
RUN
4021
[CAN'T SET(P)]
• The common pointer Nos. assigned to files
overlap.
• The local pointer Nos. assigned to files overlap.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• At power ON/At reset/STOP
RUN
4030
[CAN'T SET(I)]
The allocation pointer Nos. assigned by files
overlap.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• At power ON/At reset/STOP
RUN
4100
[OPERATION ERROR]
The instruction cannot process the contained data.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• When instruction executed
Read the common information of the error using
the peripheral device, check error step
corresponding to its numerical value (program error
location), and correct the problem.
RUN:
Off/On
ERR.:
Flicker/On
CPU Status:
Stop/
Continue
*1
4101
[OPERATION ERROR]
• The number of setting data dealt with the
instruction exceeds the applicable range.
• The storage data and constant of the device
specified by the instruction exceeds the
applicable range.
• When writing to the host CPU shared memory,
the write prohibited area is specified for the write
destination address.
• The range of storage data of the device specified
by the instruction is duplicated.
• The device specified by the instruction exceeds
the range of the number of device points.
• The interrupt pointer No. specified by the
instruction exceeds the applicable range.
■
Collateral informationmmon
• Common Information:Program error location
• Individual Information:–
■
Diagnostic Timing
• When instruction executed
Error
Code
Error Contents and Cause
Corrective Action
LED Status
CPU Status
Corresponding
CPU
*1
CPU operation can be set in the parameters at error occurrence. (LED indication varies.)
Содержание Q2ACPU
Страница 1: ......
Страница 2: ......
Страница 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Страница 269: ...16 11 16 POWER SUPPLY MODULE 2 Names and description of parts of the A62P A62PEU and A65P module ...
Страница 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Страница 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Страница 357: ...22 12 22 TROUBLESHOOTING ...
Страница 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Страница 417: ...App 20 APPENDICES 3 Shift instructions Classification Symbol Description n bit shift 1 bit shift 1 word shift ...
Страница 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Страница 432: ...App 35 APPENDICES 15 Clock instructions Classification Symbol Description Clock data read write ...
Страница 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Страница 538: ...App 141 APPENDICES APPENDIX 6 EXTERNAL DIMENSIONS Appendix 6 1 CPU Module 1 Q3ACPU Q4ACPU modules Unit mm inch ...
Страница 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Страница 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Страница 542: ...App 145 APPENDICES Appendix 6 3 Main Base Unit 1 A32B base unit 2 A32B S1 base unit Unit mm inch Unit mm inch ...
Страница 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Страница 567: ...MEMO ...
Страница 569: ......
Страница 570: ......