2.
2 -
7
OVERVIEW
2.2.1
Overview of added functions
This section shows an overview of the added functions.
(1) Variety of local device
(a) The device set as the local device at "Device" in Parameter can be monitored
and tested with a peripheral device.
This function allows checking and debug of the local device in the program
monitored with a peripheral device.
(b) The local device of the file where the subroutine program/interrupt program is
stored has made it possible to be used during execution of the subroutine
program/interrupt program.
For this function, even if an operation using the local device of the subroutine
program is carried out, the original local device cannot be overwritten. In
addition, even if an operation using the local device of the interrupt program, the
local device which is executed before starting up the interrupt program cannot be
overwritten.
(c) The following GPP function software packages are required to perform the
monitor test of the local device:
• Personal computer
GX Developer, SW2IVD-GPPQ type GPP function software package
(2) Auto refresh setting of CC-Link
(a) When setting auto refresh of the CC-Link on the peripheral function, cyclic
communication with other stations connected to the CC-Link can be
automatically performed according to the set auto refresh data.
• Remote I/O station (Communication in ON/OFF data)
• Remote device station (Communication in ON/OFF data and Word data)
• Intelligent device station (Communication in ON/OFF data and Word data)
• Local station/master station (Communication in ON/OFF data and Word data)
The auto refresh setting of the CC-Link allows communication with other stations
using the FROM/TO instruction without communicating with the master station of
the CC-Link.
(b) Auto refresh is available for up to 8 CC-Link modules for each unit of QnACPU.
Communication for 9th CC-Link module and more can be performed with the
CC-Link module using the FROM/TO instruction.
(c) The following GPP function software packages are required to perform the auto
refresh setting of the CC-Link:
• Personal computer:
GX Developer, SW2IVD-GPPQ type GPP function software package
It is necessary to upgrade the master station local station module of CC-Link to
function version B or later.
Содержание Q2ACPU
Страница 1: ......
Страница 2: ......
Страница 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Страница 269: ...16 11 16 POWER SUPPLY MODULE 2 Names and description of parts of the A62P A62PEU and A65P module ...
Страница 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Страница 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Страница 357: ...22 12 22 TROUBLESHOOTING ...
Страница 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Страница 417: ...App 20 APPENDICES 3 Shift instructions Classification Symbol Description n bit shift 1 bit shift 1 word shift ...
Страница 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Страница 432: ...App 35 APPENDICES 15 Clock instructions Classification Symbol Description Clock data read write ...
Страница 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Страница 538: ...App 141 APPENDICES APPENDIX 6 EXTERNAL DIMENSIONS Appendix 6 1 CPU Module 1 Q3ACPU Q4ACPU modules Unit mm inch ...
Страница 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Страница 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Страница 542: ...App 145 APPENDICES Appendix 6 3 Main Base Unit 1 A32B base unit 2 A32B S1 base unit Unit mm inch Unit mm inch ...
Страница 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Страница 567: ...MEMO ...
Страница 569: ......
Страница 570: ......