10.
10 -
13
OTHER FUNCTIONS
10.6 Remote Operation
With the QnACPU, the operating status of the CPU module can be controlled from
external sources (GPP function, intelligent special function module, remote contact, etc.).
REMARK
In this chapter, a serial communication module is used as an example of an intelligent
special function module.
10.6.1 Remote RUN/STOP
Remote RUN/STOP refers to the function that sets the QnACPU to RUN or STOP from an
external source while the CPU module RUN/STOP key switch is set to the RUN position.
(1) Application of remote RUN/STOP
Remote RUN/STOP operation from remote location is useful in the following cases.
(a) When the CPU module is installed in an inaccessible location
(b) When setting the CPU module in a control panel to RUN/STOP from an external
source
(2) Operation for remote RUN/STOP
The following shows the program operations to which remote RUN/STOP is
performed.
(3) Method for performing remote RUN/STOP
The following two methods are available for performing remote RUN/STOP.
(a) Method using a remote RUN contact
The remote RUN contact is set in the PLC system in the parameter mode of
GPP function.
The settable device range is from input X0 to 1FFF.
Remote RUN/STOP can be performed by switching the remote RUN contact
ON/OFF.
1) When the remote RUN contact is OFF, the CPU module is in RUN state.
2) When the remote RUN contact is ON, the CPU module is in STOP state.
(a) Remote STOP......... The program is performed up to the END instruction, then
STOP state is established.
(b) Remote RUN........... When remote RUN is performed with the CPU in STOP set
by remote STOP, the program will be in RUN state again
and be performed from step 0.
Fig. 10.4 Time chart for RUN/STOP switching with remote RUN contact
Содержание Q2ACPU
Страница 1: ......
Страница 2: ......
Страница 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Страница 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Страница 269: ...16 11 16 POWER SUPPLY MODULE 2 Names and description of parts of the A62P A62PEU and A65P module ...
Страница 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Страница 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Страница 357: ...22 12 22 TROUBLESHOOTING ...
Страница 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Страница 417: ...App 20 APPENDICES 3 Shift instructions Classification Symbol Description n bit shift 1 bit shift 1 word shift ...
Страница 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Страница 432: ...App 35 APPENDICES 15 Clock instructions Classification Symbol Description Clock data read write ...
Страница 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Страница 538: ...App 141 APPENDICES APPENDIX 6 EXTERNAL DIMENSIONS Appendix 6 1 CPU Module 1 Q3ACPU Q4ACPU modules Unit mm inch ...
Страница 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Страница 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Страница 542: ...App 145 APPENDICES Appendix 6 3 Main Base Unit 1 A32B base unit 2 A32B S1 base unit Unit mm inch Unit mm inch ...
Страница 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Страница 567: ...MEMO ...
Страница 569: ......
Страница 570: ......