Mitsubishi MSZ-A18 YV Series Скачать руководство пользователя страница 6

6

FAN

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

WIDE VANE

LONG

HEAT

I FEEL... AUTO OPERATION

Details of operation

According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY or
HEAT. However, when operation is started again within 2 hours after it  is stopped, the same operation mode before the
operation is stopped is selected. The operation mode selected first is not changed even if the room temperature changes.
If the operation mode does not match the room condition, select the appropriate operation mode by pressing the 

MODE

button.

Details of auto operation

Operation state

This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature
is obtained.

This shows that the room temperature is approaching the
target temperature.

(In case of outdoor unit MXZ series only)
Please refer to Information for multi system air conditioner.
(Page 7)

Indication

Difference between target

temperature and room temperature

About 2°C or more

About 2°C or less

Description of “I FEEL...” mode

Room temperature

Operation mode

Target temperature

when started

 (initial state)

About 25°C or higher

COOL

About 24°C

About 25°C - 23°C

DRY

About 23°C or lower

HEAT

About 26°C

NOTE:
COOL: When the room temperature is 2°C higher than the set temperature, the set temperature may not be

changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait until the room temperature drops to within 2°C of the set temperature and then change the set
temperature.

HEAT:

When the room temperature is 2°C lower than the set temperature, the set temperature may not be
changed since the air conditioner is operating to reach the target (set) temperature. In this case, please
wait until the room temperature rises to within 2°C of the set temperature and then change the set
temperature.

Details of display on the indoor unit

The operation indicator at the right side of the indoor unit indicates the operation state.

Operation indicator lamp

ON/OFF

FAN

TOO

WARM

TOO

COOL

VANE

MODE

ECONO COOL

    STOP

     START

HR.

MIN.

I FEEL COOL

DRY

AM

PM

CLOCK

˚C

AMPM

WIDE VANE

LONG

HEAT

RESET CLOCK

Operation Indicator

Lighted

Blinking

 

Not lighted

With the “

 (I FEEL...)” auto operation mode, the optimum room condition can be set automatically

with a one-touch operation.

To start operation:

Press the 

ON/OFF

 button.

When the “

 (I FEEL...)” mode is selected, the air conditioner is automatically

controlled at the optimum temperature.

To stop operation:

Press the 

ON/OFF

 button.

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

If you feel slightly warm:

Press the 

TOO

WARM

 button to lower the temperature.

One press lowers the temperature by about 1°C.

If you feel slightly cool:

Press the 

TOO

COOL

 button to raise the temperature.

One press raises the temperature by about 1°C.

When  “

 (I FEEL...)” is not selected, press the 

MODE

button until it is set.

Each time the button is pressed, the operation mode is changed
in sequence: 

 (I FEEL...) 

 

 (COOL) 

   (DRY) 

 

(HEAT)

Description of “AUTO RESTART FUNCTION”

These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main
power.

If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.

If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.

If the unit is operated in “I FEEL...”  before power failure, the operation mode (COOL, DRY or HEAT) is not stored in the
memory. When the main power is turned on, the unit decides the operation mode by the initial room temperature at
restart and starts operation again.

Содержание MSZ-A18 YV Series

Страница 1: ...Mitsubishi room air conditioner ely be sure to read this operating instructions fully for later reference d from your dealer and check that the purchased ered correctly installed by the customer Safe...

Страница 2: ...dity e g leaving a door or window open In the cooling mode if the unit is operated in a room with high humidity 80 RH or more for a long time water condensed in the air conditioner may drop and wet or...

Страница 3: ...or lamp Air inlet back and side Piping Drainage hose Air outlet Drain outlet Catechin air filter ide temperature less than 10 C in the cooling mode operated at low outside temperature less than 10 C w...

Страница 4: ...operation mode the set temperature and the fan speed are stored in the memory If a power failure occurs or the main power is turned off during operation Auto restart function sets automatically to st...

Страница 5: ...thrown or it gets wet the remote con troller may not operate When installing on a wall etc Install the remote controller holder in a position where the signal reception sound beep can be heard from t...

Страница 6: ...rget set temperature In this case please wait until the room temperature drops to within 2 C of the set temperature and then change the set temperature HEAT When the room temperature is 2 C lower than...

Страница 7: ...High notch to cool heat the room more If the operating sound of the air conditioner disturbs your sleep use the Low notch To change the AIR FLOW blowing direction vertically press the VANE button Eac...

Страница 8: ...w are available Programming timer operation The ON timer and the OFF timer can be used in combination The timer of the set time that is reached first will operate first mark indicates the order of tim...

Страница 9: ...d during operation it may cause an injury Cleaning the indoor unit Clean the unit using a soft dry cloth If the dirt is noticeable wipe the unit with a cloth soaked in a solution of mild detergent dil...

Страница 10: ...hen replace echin that is contained in tea The catechin air filter deodorizes ammonia and acetaldehyde Moreover it restraints the activity of About once every 4 months 1 Install a new air cleaning fi...

Страница 11: ...ng the air inlet or or outdoor unit open Page 10 hausted Page 5 of the batteries correct he remote controller of other being pressed oner start operating again er had operated before the se models are...

Страница 12: ...uld not be done by the customer If this is done incorrectly it may cause a fire an electric shock or an injury from the unit falling water leaking etc Consult your dealer Disposal To dispose of this p...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN SG79Y329H01...

Отзывы: