APPX
Appendix 4 Buffer Memory Areas
141
A
CH1 Input type/Range monitor
Set input type, and input range can be checked.
■
Buffer memory address
The following shows the buffer memory address of this area.
CH1 Input type/Range monitor [FX2N allocation mode]
Set input type, and input range can be checked.
■
Buffer memory address
The following shows the buffer memory address of this area.
Monitor value
Input type
Input range
000FH
Conversion not allowed (Default)
0003H
Current
4 to 20 mA
0010H
0 to 20 mA
0006H
-20 to +20 mA
0011H
Voltage
1 to 5 V
0012H
0 to 5 V
0000H
-10 to +10 V
0013H
0 to 10 V
0014H
Resistance temperature detector
Pt100
0015H
Ni100
0016H
Thermocouple
Thermocouple B
0017H
Thermocouple R
0018H
Thermocouple S
0009H
Thermocouple K
000AH
Thermocouple J
000BH
Thermocouple T
Buffer memory name
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH
Input type/Range monitor
430
630
830
1030
1230
1430
1630
1830
Monitor value
Input type
Input range
000FH
Conversion not allowed (Default)
0000H
Voltage
-10 to +10 V
0001H
0002H
0003H
Current
4 to 20 mA
0004H
0005H
0006H
-20 to +20 mA
0007H
0008H
0009H
Thermocouple
Thermocouple K
000AH
Thermocouple J
000BH
Thermocouple T
000CH
Thermocouple K
000DH
Thermocouple J
000EH
Thermocouple T
Buffer memory name
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH
Input type/Range monitor (In FX2N allocation mode
function)
1031
1032
1033
1034
1035
1036
1037
1038
Содержание MELSEC iQ-F
Страница 1: ...MELSEC iQ F FX5 User s Manual Analog Control Intelligent function module ...
Страница 2: ......
Страница 9: ...7 MEMO ...
Страница 181: ......